MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.jvca.2024.04.025

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2024

Continuous Right Ventricular Pressure Monitoring in Cardiac Surgery.

Denault André, Couture Etienne J, Perry Tjorvi, Saade Elena, Calderone Alexander, Zeng Yu Hao, Scherb Daniel, Moses Kevin, Potes Cristhian, Hammoud Ali, Beaubien-Souligny William, Elmi-Sarabi Mahsa, Grønlykke Lars, Lamarche Yoan, Lebon Jean-Sébastien, Rousseau-Saine Nicolas, Desjardins Georges, Rochon Antoine

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Right ventricular (RV) dysfunction in cardiac surgery can lead to RV failure, which is associated with increased morbidity and mortality. Abnormal RV function can be identified using RV pressure monitoring. The primary objective of the study is to determine the proportion of patients with abnormal RV early to end-diastole diastolic pressure gradient (RVDPG) and abnormal RV end-diastolic pressure (RVEDP) before initiation and after cardiopulmonary bypass (CPB) separation. The secondary objective is to evaluate if RVDPG before CPB initiation is associated with difficult and complex separation from CPB, RV dysfunction, and failure at the end of cardiac surgery.

DESIGN

Prospective study.

SETTING

Tertiary care cardiac institute.

PARTICIPANTS

Cardiac surgical patients.

INTERVENTION: Cardiac surgery.

MEASUREMENTS AND MAIN

RESULTS

Automated electronic quantification of RVDPG and RVEDP were obtained. Hemodynamic measurements were correlated with cardiac and extracardiac parameters from transesophageal echocardiography and postoperative complications. Abnormal RVDPG was present in 80% of the patients (n = 105) at baseline, with a mean RVEDP of 14.2 ± 3.9 mmHg. Patients experienced an RVDPG > 4 mmHg for a median duration of 50.2% of the intraoperative period before CPB initiation and 60.6% after CPB separation. A total of 46 (43.8%) patients had difficult/complex separation from CPB, 18 (38.3%) patients had RV dysfunction, and 8 (17%) had RV failure. Abnormal RVDPG before CPB was not associated with postoperative outcome.

CONCLUSION

Elevated RVDPG and RVEDP are common in cardiac surgery. RVDPG and RVEDP before CPB initiation are not associated with RV dysfunction and failure but can be used to diagnose them.

Для цитирования: Denault André, Couture Etienne J, Perry Tjorvi, Saade Elena, Calderone Alexander, Zeng Yu Hao, Scherb Daniel, Moses Kevin, Potes Cristhian, Hammoud Ali, Beaubien-Souligny William, Elmi-Sarabi Mahsa, Grønlykke Lars, Lamarche Yoan, Lebon Jean-Sébastien, Rousseau-Saine Nicolas, Desjardins Georges, Rochon Antoine. Continuous Right Ventricular Pressure Monitoring in Cardiac Surgery.. Journal of cardiothoracic and vascular anesthesia. 2024. DOI: 10.1053/j.jvca.2024.04.025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.