MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ccrj.2026.100176

Медицинская библиотека · Critical care and resuscitation : journal of the Australasian Academy of Critical Care Medicine · 2026

Sustainable continuous renal replacement therapy: The influence of blood flow rates, effluent dose, autoeffluent, and citrate anticoagulation on carbon dioxide emissions.

Weeraratna Cyveen, McGain Forbes, Udy Andrew A, See Emily J, Karcher Christian, Joyce Patrick R, McAlister Scott, O'Shea Catherine J, Wijayasundara Mayuri G W, Adams Natalie, James Susan R, Sansom Benjamin W

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

The aim of this study was to quantify the consumables waste for continuous renal replacement therapy (CRRT) in intensive care, determine the carbon dioxide equivalent (CO2e) per patient per day, and identify the impact of blood (Qb) and effluent flow rates, citrate anticoagulation, autoeffluent, and circuit lifespan on emissions and cost.

DESIGN

A retrospective observational study was conducted.

SETTING

The study included two major tertiary intensive care units in Melbourne from January 2017 to December 2024.

PARTICIPANTS

We analysed 70,000 h of treatment data stored on CRRT machines, captured from 2464 patients.

INTERVENTIONS: Quantities of all major consumables were obtained. A chemical composition analysis was performed, and life cycle analysis was done for each component.

MAIN OUTCOME MEASURES: Carbon dioxide-equivalent values and financial cost estimates were calculated using local, commercial pricing.

RESULTS

Combined impact of autoeffluent, lowest effluent rate (<30 mL/kg/hr), and doubling of filter life linked to Qb (130-150 mL/h) and citrate anticoagulation was associated with a 56.8% [54.4%-59.1%] decrease in CO2e.kg/day and 38.1% [34.8%-40.9%] cost reduction.Median CO2e.kg/day fell from 25.3 [21.5-29.7] in 2017 to 19.3 [16.3 - 22.8] in 2024, p <0.0001. The total cost per day of consumables also fell from $995.89 ($820.40 - $1210.67) in 2017 to $829.07 ($689.64 - $1069.19) in 2024.

CONCLUSION

Extended circuit lifespan, autoeffluent, and moderated effluent doses translate to the most sustainable delivery of CRRT with associated cost savings.

Для цитирования: Weeraratna Cyveen, McGain Forbes, Udy Andrew A, See Emily J, Karcher Christian, Joyce Patrick R, McAlister Scott, O'Shea Catherine J, Wijayasundara Mayuri G W, Adams Natalie, James Susan R, Sansom Benjamin W. Sustainable continuous renal replacement therapy: The influence of blood flow rates, effluent dose, autoeffluent, and citrate anticoagulation on carbon dioxide emissions.. Critical care and resuscitation : journal of the Australasian Academy of Critical Care Medicine. 2026. DOI: 10.1016/j.ccrj.2026.100176.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.