m+Medelevator.RU
← Поиск публикаций
Narra J · 2025

Zero-fluoroscopy versus fluoroscopy-guided catheter ablation in ventricular arrhythmia: A systematic review and meta-analysis.

СтатьяСистематический обзорМетаанализСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Irnizarifka Irnizarifka, Tristan Christopher D, Wijayanto Matthew A, Myrtha Risalina, Modesty Kyra, Rahma Annisa A, Budiono Enrico A, Rahman Awalil Rk, Hamka Muhammad F, Ilyas Muhana F

Аннотация

Catheter ablation has been the go-to treatment for ventricular arrhythmia, with traditional fluoroscopy-guided and non-zero fluoroscopy (NZF) catheter ablation posing high radiation risk for operators and patients. Zero-fluoroscopy technique offers elimination of radiation risk; however, its efficacy and safety in ventricular arrhythmia patients are not well explored. The aim of this study was to systematically evaluate the effectiveness, safety, and feasibility of zero-fluoroscopy ablation on ventricular arrhythmia patients. This study only included relevant studies comparing zero-fluoroscopy and NZF in ventricular arrhythmia ablation that were identified from Scopus, PubMed, and ScienceDirect (up to June 20, 2024). The quality of the study was assessed using the ROBINS-I tool, and the meta-analysis was conducted using a random-effect model. Out of 383 studies found, nine cohort studies were included with 1.408 patients. There was no significant difference in the acute procedural success rate of the zero-fluoroscopy and NZF (relative risk: 1.01; 95%CI: 0.95-1.07; p=0.69), with a similar recurrence rate (p=0.88; for four studies; n=374), and comparable procedural time (mean difference: -19.22 minutes; 95%CI: - 41.16-2.72; p=0.09). Adverse events such as pericardial effusion, pseudoaneurysm, and hematoma were similar between zero-fluoroscopy and NZF. Overall, zero-fluoroscopy catheter ablation has demonstrated non-inferiority as a treatment option for ventricular arrhythmia ablation. As zero-fluoroscopy eliminates radiation risk without compromising procedural efficacy, zero-fluoroscopy has the potential to become a widely adopted approach for catheter ablation in ventricular arrhythmia.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты