MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jbiomech.2020.109826

Медицинская библиотека · Journal of biomechanics · 2020

Elucidating failure mechanisms in human femurs during a fall to the side using bilateral digital image correlation.

Grassi Lorenzo, Kok Joeri, Gustafsson Anna, Zheng Yi, Väänänen Sami P, Jurvelin Jukka S, Isaksson Hanna

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

An improved understanding of the mechanical properties of human femurs is a milestone towards a more accurate assessment of fracture risk. Digital image correlation (DIC) has recently been adopted to provide full-field strain measurements during mechanical testing of femurs. However, it has typically been used to measure strains on the anterior side of the femur, whereas in both single-leg-stance and sideways fall loading conditions, the highest deformations result on the medial and lateral sides of the femoral neck. The goal of this study was to measure full-field deformations simultaneously on the medial and lateral side of the femoral neck in a configuration resembling a fall to the side. Twelve female cadaver femurs were prepared for DIC measurements and tested in sideways fall at 5 mm/s displacement rate. Two pairs of cameras recorded the medial and lateral side of the femoral neck, and deformations were calculated using DIC. The samples exhibited a two-stage failure: first, a compressive collapse on the superolateral side of the femoral neck in conjunction with peak force, followed by complete femoral neck fracture at the force drop following the post-elastic phase. DIC measurements corroborated this observation by reporting no tensile strains above yield limit for the medial side of the neck up to peak force. DIC measurements registered onto the bone micro-architecture showed strain localizations in proximity of cortical pores due to, for instance, blood vessels. This could explain previously reported discrepancies between simulations and experiments in regions rich with large pores, like the superolateral femoral neck.

Для цитирования: Grassi Lorenzo, Kok Joeri, Gustafsson Anna, Zheng Yi, Väänänen Sami P, Jurvelin Jukka S, Isaksson Hanna. Elucidating failure mechanisms in human femurs during a fall to the side using bilateral digital image correlation.. Journal of biomechanics. 2020. DOI: 10.1016/j.jbiomech.2020.109826.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.