MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/iop.0000000000000803

Медицинская библиотека · Ophthalmic plastic and reconstructive surgery · 2017

Validation of CADS Grading Scale: An Ophthalmic Specific Grading Instrument for Facial Nerve Palsy.

Tan Petrina, Siah We Fong, Wong Johnny, Malhotra Raman

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

PURPOSE: To evaluate the inter- and intraobserver reliability of the CADS score, a previously described facial nerve grading instrument for ophthalmic grading of facial nerve palsy.

METHODS

This is a cross-sectional validation study. Two clinicians independently assessed and graded each patient on the same day, masked to each other's grading. Four parameters are assessed in the CADS scale: Cornea (0-3, ±a), static Asymmetry (0-2), Dynamic function (0-3), and Synkinesis (0-2). One clinician reassessed the patients and performed the grading again at a minimum time interval of 1 hour later. A weighted κ analysis was performed to determine inter- and intraobserver reliability using 95% bootstrapped bias-corrected and accelerated (BCa) confidence intervals (CIs).

RESULTS

Thirty-three patients (27 women, mean age 51.7, range 23-80 years) with unilateral facial nerve palsy were graded. The overall interobserver reliability was 0.80 (95% BCa CI: 0.68-0.91) for cornea, 0.93 for resting asymmetry (95% BCa CI: 0.55-1.00), 0.80 for dynamic function (95% BCa CI: 0.50-0.96), and 0.88 (95% BCa CI: 0.71-0.96) for synkinesis. The overall intraobserver reliability was 0.93 for cornea (95% BCa CI: 0.83-0.98), 0.82 for resting asymmetry (95% BCa CI: 0.53-0.96), 0.92 for dynamic function (95% BCa CI: 0.72-1.00), and 0.98 for synkinesis (95% BCa CI: 0.84-1.00).

CONCLUSION

The CADS grading scale demonstrates good interobserver reliability and very good intraobserver reliability. It incorporates all ophthalmic complications for facial nerve palsy and remains easy to use and refer to.

Для цитирования: Tan Petrina, Siah We Fong, Wong Johnny, Malhotra Raman. Validation of CADS Grading Scale: An Ophthalmic Specific Grading Instrument for Facial Nerve Palsy.. Ophthalmic plastic and reconstructive surgery. 2017. DOI: 10.1097/iop.0000000000000803.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.