MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.diagmicrobio.2016.04.016

Медицинская библиотека · Diagnostic microbiology and infectious disease · 2016

A comparison of agar dilution with the Calibrated Dichotomous Sensitivity (CDS) and Etest methods for determining the minimum inhibitory concentration of ceftriaxone against Neisseria gonorrhoeae.

Enriquez Rodney P, Goire Namraj, Kundu Ratan, Gatus Barrie J, Lahra Monica M

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

The objective of this study was to compare the Calibrated Dichotomous Sensitivity (CDS) based agar dilution (CDS AD) method with the Etest (bioMérieux SA) methods using 2 method protocols for determining the minimum inhibitory concentration (MIC) of ceftriaxone against Neisseria gonorrhoeae. The two method protocols were the manufacturer's protocol for which the Clinical and Laboratory Standards Institute (CLSI) interpretative criteria for Neisseria gonorrhoeae could be applied, and the CDS-adapted protocol. Comparability of MIC data is critical for situation analysis and monitoring trends in global antimicrobial analysis.

METHODS

Two hundred and forty eight clinical isolates of N. gonorrhoeae and the World Health Organisation (WHO) N. gonorrhoeae reference strains were tested using the three methods.

RESULTS

When compared, CDS AD and CDS Etest gave a regression R(2) value of 94%, the Pearson's correlation coefficient was 97% and a paired comparison within one log2 dilution was 98%. The CDS AD and the Etest (CLSI) comparison gave a regression R(2) value of 90%, a Pearson's correlation coefficient of 95% and a paired comparison within one log2 dilution was 98%. The comparison of the CDS Etest and CLSI Etest gave a regression R(2) value of 91%, a Pearson's correlation coefficient of 95% and a paired comparison within one log2 dilution of 99%. Importantly, there was robust agreement between all three methods for the categorization of susceptibility of Neisseria gonorrhoeae isolates using the WHO nominated breakpoint for decreased susceptibility to ceftriaxone (≥0.125 μg/mL).

CONCLUSIONS

The CDS Etest method is comparable to agar dilution and the Etest methods for determining the MIC of ceftriaxone against N. gonorrhoeae.

Для цитирования: Enriquez Rodney P, Goire Namraj, Kundu Ratan, Gatus Barrie J, Lahra Monica M. A comparison of agar dilution with the Calibrated Dichotomous Sensitivity (CDS) and Etest methods for determining the minimum inhibitory concentration of ceftriaxone against Neisseria gonorrhoeae.. Diagnostic microbiology and infectious disease. 2016. DOI: 10.1016/j.diagmicrobio.2016.04.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.