m+Medelevator.RU
← Поиск публикаций
Journal of clinical medicine · 2025

Albumin Enhances Microvascular Reactivity in Sepsis: Insights from Near-Infrared Spectroscopy and Vascular Occlusion Testing.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cusack Rachael, Rodríguez Alejandro, Cantan Ben, Miskolci Orsolya, Connolly Elizabeth, Zilahi Gabor, Coakley John Davis, Martin-Loeches Ignacio

Аннотация

Background/Objectives: In septic shock, microcirculatory dysfunction contributes to organ failure and mortality. While sidestream dark-field (SDF) imaging is the reference method for assessing microvascular perfusion, its complexity limits routine use. This study evaluates near-infrared spectroscopy (NIRS) with vascular occlusion testing (VOT) as a potential bedside tool for monitoring microcirculatory changes following fluid resuscitation. Methods: Sixty-three fluid-responsive patients with sepsis were randomized to receive either 20% albumin or crystalloid. NIRS-VOT and sublingual SDF measurements were obtained at baseline and 60 min post-resuscitation. The reoxygenation slope (ReOx) derived from NIRS was calculated and compared with clinical severity scores and SDF-derived microcirculatory parameters. Results: ReOx significantly increased from baseline to 60 min in the albumin group (p = 0.025), but not in the crystalloid group. However, between-group differences at 60 min were not statistically significant. ReOx at 60 min was inversely correlated with APACHE II score (ρ = -0.325) and lactate (ρ = -0.277) and showed a weak inverse trend with norepinephrine dose. AUROC for ICU survival based on ReOx was 0.616. NIRS ReOx showed weak correlations with SDF parameters, including the number of crossings (p = 0.03) and the consensus proportion of perfused vessels (CPPV; p = 0.004). Conclusions: NIRS-VOT detected microcirculatory trends after albumin administration but showed limited agreement with SDF imaging. These findings suggest that NIRS and SDF assess different physiological domains. Further studies are warranted to define the clinical utility of NIRS as a microcirculation monitoring tool (Clinicaltrials.gov: NCT05357339).

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты