MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.sleep.2020.07.015

Медицинская библиотека · Sleep medicine · 2020

Power spectral densities of nocturnal pulse oximetry signals differ in OSA patients with and without daytime sleepiness.

Kainulainen Samu, Töyräs Juha, Oksenberg Arie, Korkalainen Henri, Afara Isaac O, Leino Akseli, Kalevo Laura, Nikkonen Sami, Gadoth Natan, Kulkas Antti, Myllymaa Sami, Leppänen Timo

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

As nocturnal hypoxemia and heart rate variability are associated with excessive daytime sleepiness (EDS) related to OSA, we hypothesize that the power spectral densities (PSD) of nocturnal pulse oximetry signals could be utilized in the assessment of EDS. Thus, we aimed to investigate if PSDs contain features that are related to EDS and whether a convolutional neural network (CNN) could detect patients with EDS using self-learned PSD features.

METHODS

A total of 915 OSA patients who had undergone polysomnography with multiple sleep latency test on the following day were investigated. PSDs for nocturnal blood oxygen saturation (SpO2), heart rate (HR), and photoplethysmogram (PPG), as well as power in the 15-35 mHz band in SpO2 (PSPO2) and HR (PHR), were computed. Differences in PSD features were investigated between EDS groups. Additionally, a CNN classifier was developed for identifying severe EDS patients based on spectral data.

RESULTS

SpO2 power content increased significantly (p < 0.002) with increasing severity of EDS. Furthermore, a significant (p < 0.001) increase in HR-PSD was found in severe EDS (mean sleep latency < 5 min). Elevated odds of having severe EDS was found in PSPO2 (OR = 1.19-1.29) and PHR (OR = 1.81-1.83). Despite these significant spectral differences, the CNN classifier reached only moderate sensitivity (49.5%) alongside high specificity (80.4%) in identifying patients with severe EDS.

CONCLUSIONS

We conclude that PSDs of nocturnal pulse oximetry signals contain features significantly associated with OSA-related EDS. However, CNN-based identification of patients with EDS is challenging via pulse oximetry.

Для цитирования: Kainulainen Samu, Töyräs Juha, Oksenberg Arie, Korkalainen Henri, Afara Isaac O, Leino Akseli, Kalevo Laura, Nikkonen Sami, Gadoth Natan, Kulkas Antti, Myllymaa Sami, Leppänen Timo. Power spectral densities of nocturnal pulse oximetry signals differ in OSA patients with and without daytime sleepiness.. Sleep medicine. 2020. DOI: 10.1016/j.sleep.2020.07.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.