MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2025.09.015

Медицинская библиотека · Heart rhythm · 2025

Comparison of far-field and peak frequency electrogram characteristics at the earliest activation sites during idiopathic ventricular arrhythmias: A novel index to predict ablation success.

Nishimura Takuro, Kanazawa Natsuki, Nagata Yasutoshi, Iwai Shinsuke, Sekiguchi Yukio, Okubo Kenji, Takahashi Yoshihide, Yamauchi Yasuteru, Miwa Naoyuki, Mizukami Akira, Negishi Miho, Honda Masaki, Tateishi Ryo, Kawamura Iwanari, Goto Kentaro, Yamao Kazuya, Tao Susumu, Takigawa Masateru, Miyazaki Shinsuke, Sasano Tetsuo

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Evaluating the peak frequency electrograms (EGMs) has the potential to differentiate near-field from far-field components.

OBJECTIVE

This study examined how peak frequency analyses of EGMs preceding idiopathic ventricular arrhythmias (VAs) affect catheter ablation outcomes.

METHODS

A retrospective analysis was conducted on 111 VAs from 104 patients. EGMs at the earliest activation site, detected using high-density activation maps, were analyzed to assess the association with a successful elimination after a single radiofrequency delivery.

RESULTS

In outflow tract VAs (n = 77), the first deflection timing was similar for VAs with and without a successful elimination. The peak frequency timing was earlier (right ventricular outflow tract -21 ms [-32 to -16 ms] vs -11 ms [-20 to 0 ms], P = .002; left ventricular outflow tract -26 ms [-33 to -4 ms] vs 0 ms [-6 to 10 ms], P = .005) and the difference between the first deflection and peak frequency timing (delta F-P) shorter (right ventricular outflow tract 7 ms [5-13 ms] vs 17 ms [11-24 ms], P < .001; left ventricular outflow tract 10 ms [6-19 ms] vs 22 ms [20-27 ms], P = .001) for VAs with a successful elimination than for those without. The delta F-P correlated with the time to elimination of outflow tract VAs (P = .01; r = 0.45). None of the outflow tract VAs with a delta F-P of >22 ms achieved a successful elimination. For non-outflow tract VAs (n = 34), no parameters were associated with a successful elimination.

CONCLUSION

The first component of the EGM at the earliest activation site may reflect a far-field recording from the site of origin of idiopathic VAs. A novel delta F-P EGM index may predict quick, successful endocardial ablation of outflow tract VAs.

Для цитирования: Nishimura Takuro, Kanazawa Natsuki, Nagata Yasutoshi, Iwai Shinsuke, Sekiguchi Yukio, Okubo Kenji, Takahashi Yoshihide, Yamauchi Yasuteru, Miwa Naoyuki, Mizukami Akira, Negishi Miho, Honda Masaki, Tateishi Ryo, Kawamura Iwanari, Goto Kentaro, Yamao Kazuya, Tao Susumu, Takigawa Masateru, Miyazaki Shinsuke, Sasano Tetsuo. Comparison of far-field and peak frequency electrogram characteristics at the earliest activation sites during idiopathic ventricular arrhythmias: A novel index to predict ablation success.. Heart rhythm. 2025. DOI: 10.1016/j.hrthm.2025.09.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.