MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00134-026-08544-w

Медицинская библиотека · Intensive care medicine · 2026

High-flow nasal cannula oxygen during breaks from noninvasive ventilation after extubation: an observational study.

Thille Arnaud W, Chamblet Louis, Ragot Stéphanie, Gacouin Arnaud, Nay Mai-Anh, Ehrmann Stephan, Girault Christophe, Dangers Laurence, Labro Guylaine, Canet Emmanuel, Quenot Jean-Pierre, Decavele Maxens, Guitton Christophe, Prat Gwenael, Saccheri Clément, Contou Damien, Rouze Anahita, Azais Marie-Ange, Romen Antoine, Lacave Guillaume, Lautrette Alexandre, Sedillot Nicholas, Sonneville Romain, Vivier Emmanuel, Hoppe Marie-Anne, Bourenne Jeremy, Beloncle François, Coudroy Rémi, Frat Jean-Pierre

СтатьяНаблюдательное исследованиеМногоцентровое исследованиеПеревод в очереди

Аннотация

PURPOSE: Clinical practice guidelines recommend prophylactic noninvasive ventilation (NIV) after extubation in high-risk patients. The effects of high-flow nasal cannula (HFNC) oxygen during breaks from NIV after extubation have been poorly explored. Our objective was to assess whether HFNC rather than standard oxygen during breaks from NIV may prevent extubation failure.

METHODS

Observational study based on two multicenter clinical trials including patients at high-risk of extubation failure (> 65 years or with underlying cardiac or respiratory disease). We included the 1077 patients who received prophylactic NIV after extubation, alternating with HFNC (NIV/HFNC) or standard oxygen (NIV/O2). The primary outcome was the proportion of patients who failed extubation (reintubation or death within the seven days following extubation). We used G-computation to estimate the causal effect of HFNC on the risk of extubation failure, while accounting for confounding factors.

RESULTS

After extubation, 655 patients (61%) received NIV/HFNC while 422 (39%) received NIV/O2. The extubation failure rate at day 7 was significantly lower with NIV/HFNC than with NIV/O2 (13.7% vs. 18.5%; difference, - 4.7% [95% CI, - 9.4% to - 0.3%]; p = 0.036). Using G-computation, NIV/HFNC was not more effective than NIV/O2 in reducing the risk of extubation failure, with an estimated adjusted difference of - 3.9% [95% CI, - 8.7% to 0.9%]. Reintubation rates were significantly lower with NIV/HFNC than with NIV/O2 at 48h, but did not significantly differ beyond 48h.

CONCLUSIONS

Although the adjusted analysis did not confirm the favorable unadjusted findings, HFNC during breaks from NIV might decrease the risk of extubation failure, and warrants future clinical trials.

Для цитирования: Thille Arnaud W, Chamblet Louis, Ragot Stéphanie, Gacouin Arnaud, Nay Mai-Anh, Ehrmann Stephan, Girault Christophe, Dangers Laurence, Labro Guylaine, Canet Emmanuel, Quenot Jean-Pierre, Decavele Maxens, Guitton Christophe, Prat Gwenael, Saccheri Clément, Contou Damien, Rouze Anahita, Azais Marie-Ange, Romen Antoine, Lacave Guillaume, Lautrette Alexandre, Sedillot Nicholas, Sonneville Romain, Vivier Emmanuel, Hoppe Marie-Anne, Bourenne Jeremy, Beloncle François, Coudroy Rémi, Frat Jean-Pierre. High-flow nasal cannula oxygen during breaks from noninvasive ventilation after extubation: an observational study.. Intensive care medicine. 2026. DOI: 10.1007/s00134-026-08544-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.