m+Medelevator.RU
← Поиск публикаций
Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology · 2021

Predictive factors of amoxicillin immediate hypersensitivity and validation of PEN-FAST clinical decision rule.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Piotin Anays, Godet Julien, Trubiano Jason A, Grandbastien Manon, Guénard-Bilbault Lydie, de Blay Frédéric, Metz-Favre Carine

Аннотация

BACKGROUND: The challenge of delabeling amoxicillin allergy is an important issue for patients and clinicians, especially when anaphylaxis is reported. A recent study has proposed a clinical decision rule, PEN-FAST, to identify low-risk penicillin allergies.

OBJECTIVE: To validate the PEN-FAST clinical decision rule in a population with high risk of suspected immediate amoxicillin allergy and to identify clinical predictive factors of amoxicillin immediate hypersensitivity.

METHODS: We retrospectively analyzed medical records of patients with a suspected immediate amoxicillin allergy who carried out an allergologic evaluation by a specialist in the Allergy Unit of Strasbourg University Hospital from 2015 to 2020.

RESULTS: A total of 142 adult patients (88 women [62.0%]; median age, 52 [interquartile range, 40.3-62.0] years) were analyzed. Most of them reported anaphylaxis (68.8%). Internal validation of PEN-FAST score revealed a good discrimination with area under the curve of 0.86 (95% confidence interval, 0.79-0.92). A cutoff of less than 3 points for PEN-FAST was used to classify 29 from 142 patients at low risk of allergy, of whom only 2 (6.9%) received positive results of allergy testing. The negative predictive value for successful delabeling was 0.93 (95% confidence interval, 0.77-0.99). Predictive clinical features for immediate amoxicillin hypersensitivity were time since reaction (P < .001), time elapsed between drug intake and first symptom (P < .001), severity grade reaction (P < .001), and treatment or hospitalization required (P < .001).

CONCLUSION: PEN-FAST has been validated to identify low-risk penicillin allergies in our European cohort of patients mainly reporting anaphylaxis. This is the first reported external validation of a penicillin allergy clinical decision rule internationally.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты