Two-year outcome data suggest that less invasive surfactant administration (LISA) is safe. Results from the follow-up of the randomized controlled AMV (avoid mechanical ventilation) study.

Herting Egbert, Kribs Angela, Härtel Christoph, von der Wense Axel, Weller Ursula, Hoehn Thomas, Vochem Matthias, Möller Jens, Wieg Christian, Roth Bernhard, Göpel Wolfgang, German Neonatal Network (GNN)

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

Less invasive surfactant administration (LISA) is a method to deliver surfactant to spontaneously breathing premature infants via a thin catheter. Here we report the two-year outcome from the AMV (avoid mechanical ventilation) study, the first randomized controlled trial on this mode of surfactant delivery. No statistically significant differences in weight, length or neurodevelopmental outcome (Bayley II scores) were found between the LISA intervention group (n = 95) and the control group (n = 84) that received standard treatment.

Conclusion

No differences in outcome were observed at 2 years. LISA seems safe in that aspect. What is Known: • LISA is a method that is in increasing use for surfactant delivery to spontaneously breathing infants. LISA reduces the need for mechanical ventilation. What is New: • Outcome data at 2 years from the first randomized study with LISA raise no safety concerns in comparison to a group of infants that received standard treatment.

Для цитирования: Herting Egbert, Kribs Angela, Härtel Christoph, von der Wense Axel, Weller Ursula, Hoehn Thomas, Vochem Matthias, Möller Jens, Wieg Christian, Roth Bernhard, Göpel Wolfgang, German Neonatal Network (GNN). Two-year outcome data suggest that less invasive surfactant administration (LISA) is safe. Results from the follow-up of the randomized controlled AMV (avoid mechanical ventilation) study.. European journal of pediatrics. 2020. DOI: 10.1007/s00431-020-03572-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.