m+Medelevator.RU
← Поиск публикаций
Scientific reports · 2025

Sustainable UV approaches backed by one step extraction procedure for quantifying the newly released mirabegron and silodosin mixture in urine.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mohamed Ahmed R, El-Hanboushy Sara, Darweish Eman

Аннотация

Mirabegron (MIR) and silodosin (SIL) have recently been combined in a single pill to significantly enhance the effectiveness of treating detrusor hyperactivity with impaired contractility (DHIC), leading to appreciable improvements in symptoms associated with overactive bladder. Additionally, this combination effectively manages lower ureteric stones and improves patient outcomes with no significant side effects, especially in elderly patients. Accordingly, this study introduces two UV techniques for analyzing MIR and SIL in their mixtures (pure and commercial mixtures). These techniques were backed by a one-step salting-out liquid/liquid extraction (SALLE) procedure for quantifying MIR and SIL in urine samples without matrix interference. The proposed UV techniques succeeded in resolving the superimposed MIR's and SIL's UV spectra by employing straightforward mathematical filtration. The UV techniques were Fourier self-deconvolution (FSD) and induced dual-wavelength (IDW) techniques, with linearities of (50-350) µg/mL for MIR and (5-100) µg/mL for SIL. The applied techniques were verified following the International Council for Harmonisation (ICH) directives and were statistically evaluated against the published technique, with no noteworthy differences found. The applied techniques' practicality (blueness), whiteness, and greenness were appraised utilizing various metrics. Per the preceding, the applied approaches have been proven to be sustainable, delicate, and appropriate for quality control (QC) testing. Also, backing the applied approaches with the SALLE procedure enables precise monitoring of MIR and SIL in miscellaneous biological fluids with excellent recoveries, presenting an inventive approach for further bioanalytical applications.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты