MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11419-022-00622-0

Медицинская библиотека · Forensic toxicology · 2022

High-sensitivity method for the determination of LSD and 2-oxo-3-hydroxy-LSD in oral fluid by liquid chromatography‒tandem mass spectrometry.

da Cunha Kelly Francisco, Kahl Julia Martinelli Magalhães, Fiorentin Taís Regina, Oliveira Karina Diniz, Costa Jose Luiz

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: We have developed and validated a high-sensitivity method to quantify lysergic acid diethylamide (LSD) and 2-oxo-3-hydroxy-LSD (OH-LSD) in oral fluid samples using liquid-liquid extraction and liquid chromatography-tandem mass spectrometry (LC‒MS/MS). The method was applied to the quantification of both substances in 42 authentic oral fluid samples.

METHODS

A liquid-liquid extraction was performed using 500 µL each of samples (oral fluid samples collected using Quantisal™ device) and dichloromethane/isopropanol mixture (1:1, v/v). Enzymatic hydrolysis was evaluated to cleave glucuronide metabolites.

RESULTS

The limit of quantification was 0.01 ng/mL for both LSD and OH-LSD. The linearity was assessed between 0.01 and 5 ng/mL. Imprecision and bias were not higher than 10.2% for both analytes. Extraction recovery was higher than 69%. The analytes were stable in the autosampler at 10 °C for 24 h, and up to 30 days at 4 and -20 °C. The method was applied to the analysis of 42 oral fluid samples. LSD was detected in all samples (concentrations between 0.02 and 175 ng/mL), and OH-LSD was detected in 20 samples (concentrations between 0.01 and 1.53 ng/mL).

CONCLUSIONS

A high-sensitive method was fully validated and applied to authentic samples. To our knowledge, this is the first work to report concentrations of LSD and OH-LSD in authentic oral fluid samples.

Для цитирования: da Cunha Kelly Francisco, Kahl Julia Martinelli Magalhães, Fiorentin Taís Regina, Oliveira Karina Diniz, Costa Jose Luiz. High-sensitivity method for the determination of LSD and 2-oxo-3-hydroxy-LSD in oral fluid by liquid chromatography‒tandem mass spectrometry.. Forensic toxicology. 2022. DOI: 10.1007/s11419-022-00622-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.