MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/bmc.70072

Медицинская библиотека · Biomedical chromatography : BMC · 2025

Quality by Design Based Chromatography Technique Development and Validation for the Medicine Venetoclax (for Chronic Leukemia), in the Context of Impurities Including Degradation Products.

Dandabattina Rajeshwari, Merugu Karuna Sree, Bandaru Lova Gani Raju, Sharathbabu Haridasyam, Gundla Rambabu, Katari Naresh Kumar

СтатьяПеревод в очереди

Аннотация

The present research study describes the Venetoclax (VEN)-related substances test method using RP-HPLC/DAD techniques. It was developed and validated according to ICH Q14 and Q2(R2) guidelines. The substances were separated using an X-Bridge Phenyl column (150 mm × 4.6 mm, 3.5 μm) and a gradient program. The mobile phase A, consist 0.02 mM Na2HPO4 (pH 8.0) buffer and acetonitrile in an 80:20 v/v ratio. Mobile phase B was prepared using a 75:25 v/v mixture of acetonitrile and a pH 8.0 buffer and well mixed. The flow rate remains constant at 1.0 mL/min, traversing an appropriate gradient program. The VEN and its impurities were detected at 280 nm, with an injection volume of 15 μL and a runtime of 130 min. Moreover, we identified proper degradation impurities and sensitivity of VEN due to forced-degradation study experiments. The linearity and range of the testing procedure were validated by computing r2 values over 0.999. All organic impurities were recovered at a rate of 97.6%-106.0% with a relative standard deviation of 0.11%-4.35%. A robustness test was conducted utilizing the AQbD methodology. The proposed method was stability-indicating in nature and can be used for commercial samples in the pharmaceutical industries.

Для цитирования: Dandabattina Rajeshwari, Merugu Karuna Sree, Bandaru Lova Gani Raju, Sharathbabu Haridasyam, Gundla Rambabu, Katari Naresh Kumar. Quality by Design Based Chromatography Technique Development and Validation for the Medicine Venetoclax (for Chronic Leukemia), in the Context of Impurities Including Degradation Products.. Biomedical chromatography : BMC. 2025. DOI: 10.1002/bmc.70072.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.