Catheter ablation in congenital heart diseases: a French nationwide study.

Waldmann Victor, Duthoit Guillaume, Pasquié Jean-Luc, Champ-Rigot Laure, Albertini Mathieu, Anselme Frédéric, Bartoletti Stefano, Bonnet Damien, Bredy Charlène, Bun Sok-Sithikun, Clerici Gaël, Da Costa Antoine, De Chillou Christian, Defaye Pascal, de Guillebon Maxime, Davril Clément, Delinière Antoine, Derval Nicolas, Ditac Geoffroy, Gardey Kevin, Ghanimé Caroline, Gourraud Jean-Baptiste, Hascoet Sébastien, Hammache Néfissa, Henaine Roland, Iserin Laurence, Jacon Peggy, Jourda Frédéric, Karsenty Clément, Koutbi Linda, Laurent Gabriel, Maille Baptiste, Maltret Alice, Mansourati Jacques, Marimpouy Nathan, Martins Raphael, Maury Philippe, Milhem Antoine, Moceri Pamela, Ollitrault Pierre, Pinon Pauline, Piot Olivier, Richard-Vitton Robin, Sacher Frédéric, Sebag Frédéric, Tortigue Marine, Venier Sandrine, Wilkin Marie, Winum Pierre, Marijon Eloi, Combes Nicolas, Bessière Francis

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND AND AIMS: Current evidence on catheter ablation for patients with congenital heart disease (CHD) is derived from small, retrospective studies. This study aims to provide insights from a nationwide contemporary registry.

METHODS

This prospective study included all CHD patients referred for catheter ablation from 2020 to July 2024 across 28 French centres. The primary outcome was the rate of per-procedural acute success. Secondary outcomes included complications as well as freedom from arrhythmia recurrence.

RESULTS

A total of 1135 consecutive catheter ablation procedures were performed in 998 patients (mean age 46.1 ± 16 years, 55.5% male). The main primary clinical arrhythmias targeted were atrial flutter/tachycardia in 677 (59.6%), atrial fibrillation in 195 (17.2%), ventricular arrhythmia in 188 (16.6%), and atrioventricular reentrant tachycardia in 38 (3.3%), with significant variations in patterns observed based on the underlying substrate. Clinical arrhythmia was successfully ablated in 1071 patients (94.4%). The mean number of arrhythmias targeted per procedure was 1.5 ± 0.7, with overall acute success rates exceeding 90% for all arrhythmias except for ventricular arrhythmias (86.7%). Acute complication occurred in 43 procedures (3.8%), including 1 (0.1%) death. The overall 1- and 2-year recurrence-free rates were 77.3% (95% confidence interval 74.2%-80.4%) and 68.4% (95% confidence interval 64.7%-72.3%), respectively. Significant variations in recurrence rates were noted based on the type of arrhythmia and the underlying CHD.

CONCLUSIONS

Catheter ablation in patients with CHD demonstrates highly favourable acute outcomes and a low complication rate. Recurrence rates during follow-up vary depending on the targeted arrhythmia and the underlying CHD. These findings should be considered in the benefit-risk assessment.

Для цитирования: Waldmann Victor, Duthoit Guillaume, Pasquié Jean-Luc, Champ-Rigot Laure, Albertini Mathieu, Anselme Frédéric, Bartoletti Stefano, Bonnet Damien, Bredy Charlène, Bun Sok-Sithikun, Clerici Gaël, Da Costa Antoine, De Chillou Christian, Defaye Pascal, de Guillebon Maxime, Davril Clément, Delinière Antoine, Derval Nicolas, Ditac Geoffroy, Gardey Kevin, Ghanimé Caroline, Gourraud Jean-Baptiste, Hascoet Sébastien, Hammache Néfissa, Henaine Roland, Iserin Laurence, Jacon Peggy, Jourda Frédéric, Karsenty Clément, Koutbi Linda, Laurent Gabriel, Maille Baptiste, Maltret Alice, Mansourati Jacques, Marimpouy Nathan, Martins Raphael, Maury Philippe, Milhem Antoine, Moceri Pamela, Ollitrault Pierre, Pinon Pauline, Piot Olivier, Richard-Vitton Robin, Sacher Frédéric, Sebag Frédéric, Tortigue Marine, Venier Sandrine, Wilkin Marie, Winum Pierre, Marijon Eloi, Combes Nicolas, Bessière Francis. Catheter ablation in congenital heart diseases: a French nationwide study.. European heart journal. 2026. DOI: 10.1093/eurheartj/ehaf343.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.