MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.crad.2015.10.009

Медицинская библиотека · Clinical radiology · 2015

In the digital era, architectural distortion remains a challenging radiological task.

Suleiman W I, McEntee M F, Lewis S J, Rawashdeh M A, Georgian-Smith D, Heard R, Tapia K, Brennan P C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIM: To compare readers' performance in detecting architectural distortion (AD) compared with other breast cancer types using digital mammography.

MATERIALS AND

METHODS

Forty-one experienced breast screen readers (20 US and 21 Australian) were asked to read a single test set of 30 digitally acquired mammographic cases. Twenty cases had abnormal findings (10 with AD, 10 non-AD) and 10 cases were normal. Each reader was asked to locate and rate any abnormalities. Lesion and case-based performance was assessed. For each collection of readers (US; Australian; combined), jackknife free-response receiver operating characteristic (JAFROC), figure of merit (FOM), and inferred receiver operating characteristic (ROC), area under curve (Az) were calculated using JAFROC v.4.1 software. Readers' sensitivity, location sensitivity, JAFROC, FOM, ROC, Az scores were compared between cases groups using Wilcoxon's signed ranked test statistics.

RESULTS

For lesion-based analysis, significantly lower location sensitivity (p=0.001) was shown on AD cases compared with non-AD cases for all reader collections. The case-based analysis demonstrated significantly lower ROC Az values (p=0.02) for the first collection of readers, and lower sensitivity for the second collection of readers (p=0.04) and all-readers collection (p=0.008), for AD compared with non-AD cases.

CONCLUSIONS

The current work demonstrates that AD remains a challenging task for readers, even in the digital era.

Для цитирования: Suleiman W I, McEntee M F, Lewis S J, Rawashdeh M A, Georgian-Smith D, Heard R, Tapia K, Brennan P C. In the digital era, architectural distortion remains a challenging radiological task.. Clinical radiology. 2015. DOI: 10.1016/j.crad.2015.10.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.