MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/pd.4883

Медицинская библиотека · Prenatal diagnosis · 2016

Diagnostic accuracy of intracranial translucency in detecting spina bifida: a systematic review and meta-analysis.

Maruotti Giuseppe M, Saccone Gabriele, D'Antonio Francesco, Berghella Vincenzo, Sarno Laura, Morlando Maddalena, Giudicepietro Antonia, Martinelli Pasquale

СтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the diagnostic accuracy of intracranial translucency (IT) in the detection of spina bifida (SB) in the first trimester of pregnancy.

METHODS

We included study assessing the accuracy of sonographic measurements of IT in a mid-sagittal view of the fetal face in prediction of SB in the first trimester of pregnancy. The primary outcome was the accuracy of IT in prediction of spina bifida. Summary estimates of sensitivity, specificity, positive and negative likelihood ratios (LR), and diagnostic odds ratio for the overall predictive accuracy of IT were computed.

RESULTS

Nine studies (21 070 fetuses) were included in the analysis. IT was successfully assessed in the majority of fetuses 97.8% (95% CI 97.6-98.0). The diagnostic performance of IT in detecting SB was as follows: sensitivity: 53.5% (95% CI 42.4-64.3), specificity: 99.7% (95% CI 99.6-99.8), positive LR: 62.1 (95% CI 12.2-317), negative LR:0.55 (95% CI 0.45-0.68), and diagnostic odds ratio: 223 (95% CI 25-2039).

CONCLUSIONS

Intracranial translucency had low diagnostic accuracy in prediction of open spina bifida, thus questioning its role as a screening marker for open SB in an unselected population. When looking at the individual study data, it appears that IT assessment for open SB prediction can be affected by a high rate of false positive results potentially leading to unnecessary parental anxiety. © 2016 John Wiley & Sons, Ltd.

Для цитирования: Maruotti Giuseppe M, Saccone Gabriele, D'Antonio Francesco, Berghella Vincenzo, Sarno Laura, Morlando Maddalena, Giudicepietro Antonia, Martinelli Pasquale. Diagnostic accuracy of intracranial translucency in detecting spina bifida: a systematic review and meta-analysis.. Prenatal diagnosis. 2016. DOI: 10.1002/pd.4883.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.