MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13058-015-0654-4

Медицинская библиотека · Breast cancer research : BCR · 2015

Mammographic density defined by higher than conventional brightness threshold better predicts breast cancer risk for full-field digital mammograms.

Nguyen Tuong Linh, Aung Ye Kyaw, Evans Christopher Francis, Yoon-Ho Choi, Jenkins Mark Anthony, Sung Joohon, Hopper John Llewelyn, Song Yun-Mi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

When measured using the computer-assisted method CUMULUS, mammographic density adjusted for age and body mass index predicts breast cancer risk. We asked if new mammographic density measures defined by higher brightness thresholds gave better risk predictions.

METHODS

The Korean Breast Cancer Study included 213 women diagnosed with invasive breast cancer and 630 controls matched for age at full-field digital mammogram and menopausal status. Mammographic density was measured using CUMULUS at the conventional threshold (Cumulus), and in effect at two increasingly higher thresholds, which we call Altocumulus and Cirrocumulus, respectively. All measures were Box-Cox transformed and adjusted for age, body mass index, menopausal status and machine. We used conditional logistic regression to estimate the change in Odds PER standard deviation of transformed and Adjusted density measures (OPERA). The area under the receiver operating characteristic curve (AUC) was estimated.

RESULTS

Corresponding Altocumulus and Cirrocumulus density measures were correlated with Cumulus measures (r approximately 0.8 and 0.6, respectively). Altocumulus and Cirrocumulus measures were on average 25% and 80% less, respectively, than the Cumulus measure. For dense area, the OPERA was 1.18 (95% confidence interval: 1.01-1.39, P = 0.03) for Cumulus; 1.36 (1.15-1.62, P < 0.001) for Altocumulus; and 1.23 (1.04-1.45, P = 0.01) for Cirrocumulus. After fitting the Altocumulus measure, the Cumulus measure was no longer associated with risk. After fitting the Cumulus measure, the Altocumulus measure was still associated with risk (P = 0.001). The AUCs for dense area was 0.59 for the Altocumulus measure, greater than 0.55 and 0.57 for the Cumulus and Cirrocumulus measures, respectively (P = 0.001). Similar results were found for percentage dense area measures.

CONCLUSIONS

Altocumulus measures perform better than Cumulus measures in predicting breast cancer risk, and Cumulus measures are confounded by Altocumulus measures. The mammographically bright regions might be more aetiologically important for breast cancer, with implications for biological, molecular, genetic and epidemiological research and clinical translation.

Для цитирования: Nguyen Tuong Linh, Aung Ye Kyaw, Evans Christopher Francis, Yoon-Ho Choi, Jenkins Mark Anthony, Sung Joohon, Hopper John Llewelyn, Song Yun-Mi. Mammographic density defined by higher than conventional brightness threshold better predicts breast cancer risk for full-field digital mammograms.. Breast cancer research : BCR. 2015. DOI: 10.1186/s13058-015-0654-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.