MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bot.0b013e3182112d7b

Медицинская библиотека · Journal of orthopaedic trauma · 2011

Anatomic relationships after instrumentation of the midshaft clavicle with 3.5-mm reconstruction plating: an anatomic study.

Werner Steven Douglas, Reed Jason, Hanson Tobin, Jaeblon Todd

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To examine the anatomic relationships of the major neurovascular structures at the midshaft clavicle region as they pertain to plate osteosynthesis in the treatment of midshaft clavicle fractures.

METHODS

Fifteen fresh cadaveric specimens were dissected at the clavicle region. The shortest distances from the midshaft clavicular fracture lines to the subclavian artery and vein and brachial plexus were measured with a digital caliper with the limb in anatomic position and at 90° of abduction. The mean and range distance values were recorded. The clavicles were then instrumented with eight-hole, 3.5-mm reconstruction plates and screws (Synthes, Paoli PA) placed in superior and anteroinferior positions. The shortest distances from the screw tips to the neurovascular structures were measured at variable plate positions, fracture zones, and limb positions. The incidence of screw tip contact was reported.

RESULTS

In 20% (three of 15) of the specimens, screw tip contact with a major neurovascular structure occurred. In these three specimens, two screw tip contacts occurred with the plate in a superior position and two occurred with the plate in an anteroinferior position. In one specimen, screw tip contact occurred with both plate positions. Limb abduction to 90° consistently increased the distance of the neurovascular structures from the clavicle. There was no observable trend in screw contact frequency in respect to limb position or fracture zone.

CONCLUSION

Caution must be exercised when instrumenting midshaft clavicle fractures regardless of chosen plate position. Limb abduction to 90° provides an added measure of safety during clavicle instrumentation.

Для цитирования: Werner Steven Douglas, Reed Jason, Hanson Tobin, Jaeblon Todd. Anatomic relationships after instrumentation of the midshaft clavicle with 3.5-mm reconstruction plating: an anatomic study.. Journal of orthopaedic trauma. 2011. DOI: 10.1097/bot.0b013e3182112d7b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.