A 66-year-old man underwent repair of an abdominal aortic aneurysm and synchronous stenting of a thoracic aneurysm compressing his left main bronchus. This resulted in further bronchial compression which was also stented. An aorto-bronchial fistula resulting in severe haemoptysis occurred a few weeks later. This was successfully treated with repeat endovascular stenting and left pneumonectomy. Open repair should be the treatment of choice for thoracic aneurysms with bronchial compression.

Для цитирования: Abdul-Ghani Ayman, Pisipati Sailaja, McWilliams Richard, Page Richard D. Aorto-bronchial fistula following aortic and bronchial stenting of a thoracic aneurysm.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2006. DOI: 10.1016/j.ejcts.2005.11.038.