OBJECTIVES

To determine the inflammatory responses in endovascular abdominal aortic aneurysm (AAA) repair and their relation to clinical findings.

DESIGN

Prospective non-randomised study.

SETTING

University Hospital, Department of Surgery.

PATIENTS AND

METHODS

Seven patients treated with an endoluminal procedure (AAA-E) and seven patients undergoing conventional surgery (AAA-C) were included. Inflammatory parameters were assessed by measurements of the cytokines interleukin (IL)-1 beta, IL-6, IL-8 and Tumour Necrosis Factor-alpha (TNF-alpha); analyses of complement proteins C1q, C4, C3, C5a and Terminal Complement Complexes (TCC); haematologic parameters and determination of C-reactive protein (CRP).

RESULTS

In six of seven patients in the AAA-E group blood pressure decreases were recorded during introduction of the device. IL-6 and CRP levels were found to be significantly higher in AAA-C patients compared to the AAA-E group. On the other hand, high TNF-alpha levels were recorded in the AAA-E group. Less consumption of the complement proteins C1q, C4 and C3 was observed in AAA-E compared to AAA-C patients. Increased C5a levels were recorded in the AAA-C group, whereas only slight fluctuations were noticed in the AAA-E group. TCC levels were unchanged in both groups.

CONCLUSION

Endovascular aortic aneurysm repair induced a significant inflammatory response, mainly involving TNF-alpha and differing from the findings during open AAA repair. These inflammatory responses were probably related to blood pressure decreases during the procedures. On the other hand, conventional repair induced responses related to the more extensive surgical trauma and reperfusion injury.

Для цитирования: Swartbol P, Norgren L, Albrechtsson U, Cwikiel W, Jahr J, Jonung T, Pärsson H, Ribbe E, Thörne J, Truedsson L, Zdanowski Z. Biological responses differ considerably between endovascular and conventional aortic aneurysm surgery.. European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery. 1996. DOI: 10.1016/s1078-5884(96)80270-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.