MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2017.01.084

Медицинская библиотека · Journal of chromatography. A · 2017

High resolution mass spectrometry based method applicable for a wide range of 3-hydroxy-3-methyl-glutaryl-coenzyme A reductase inhibitors in blood serum including intermediates and products of the cholesterol biosynthetic pathway.

Kosek Vít, Stránská Milena, Fenclová Marie, Ruml Tomáš, Vítek Libor, Hajšlová Jana

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

Statins belong to the major class of hypolipidemic drugs. They act as competitive inhibitors of 3-hydroxy-3-methyl-glutaryl-coenzyme A (HMG-CoA) reductase, a rate-limiting enzyme in the cholesterol biosynthetic pathway. This inhibition not only leads to the depletion of cholesterol and its fatty acid esters, but also to the depletion of the intermediates of this metabolic pathway (mainly pyrophosphates), which can play an important role in tumor proliferation. The aim of the current study was to establish a versatile multi-analyte method capable of quantitative determination of various currently-used statins, together with free cholesterol (FC), cholesterol esters (CEs), and some key intermediates of the mevalonate pathway occurring in human serum. Various methods of sample preparation were examined in order to minimize the content of potentially interfering serum proteins, and simultaneously to assure acceptable recovery of the target analytes. Following protein precipitation with 2-propanol, separation of the sample components using ultra-high performance liquid chromatography coupled with tandem high resolution mass spectrometry (U-HPLC-HRMS/MS) was performed, employing a hyphenated quadrupole Orbitrap mass analyzer. The potential of the developed method was validated on human serum samples from patients treated with statins. This versatile method possesses wide applicability, in both clinical and experimental medicine.

Для цитирования: Kosek Vít, Stránská Milena, Fenclová Marie, Ruml Tomáš, Vítek Libor, Hajšlová Jana. High resolution mass spectrometry based method applicable for a wide range of 3-hydroxy-3-methyl-glutaryl-coenzyme A reductase inhibitors in blood serum including intermediates and products of the cholesterol biosynthetic pathway.. Journal of chromatography. A. 2017. DOI: 10.1016/j.chroma.2017.01.084.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.