MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.otsr.2017.10.013

Медицинская библиотека · Orthopaedics & traumatology, surgery & research : OTSR · 2017

A new method to locate the radial head "safe zone" on computed tomography axial views.

Zhan Y, Luo C F, Chen Y J

СтатьяПеревод в очереди

Аннотация

PURPOSE: Direct location of the "safe zone" on a CT axial view is impossible because the radial head is circular in shape. Previous "safe zone" location methods are not appropriate if the physician is unable to visualize the actual radial head. This study aims to introduce a new method to locate the "safe zone" on CT.

METHODS

CT scans were performed on 20 intact cadaveric upper limbs from 20 different corpses in full pronation and supination. The DICOM-format raw data were then re-sliced and analyzed in Mimics 17.0 (Materialise, Belgium). The radial interosseous border (IB) is shaped like a droplet on the axial view; its axis was selected as our reference line (RL). A parallel line in the radial head axial slice was created, and its position relative to the "safe zone" was studied. Deviation in RL direction was evaluated.

RESULTS

Safe-zone scope was 114.41°±11.99. The rotation angle from the RL to the safe-zone's anterior and posterior border was 215.03°±5.99 and 100.62°±8.12, respectively. Rotation direction (clockwise or anti-clockwise) depended on relative radius-ulna position. The safe zone was located by determining these two borders. The reference line's direction was stable in the upper half of the IB; its distance to the radial head fovea was 77.33° mm±6.24.

CONCLUSIONS

The radial head "safe zone" can be located on CT axial view based on the upper half of the IB using this new method. The method is clinically applicable to determine whether postoperative elbow malrotation results from plate impingement.

Для цитирования: Zhan Y, Luo C F, Chen Y J. A new method to locate the radial head "safe zone" on computed tomography axial views.. Orthopaedics & traumatology, surgery & research : OTSR. 2017. DOI: 10.1016/j.otsr.2017.10.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.