MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/pd.6129

Медицинская библиотека · Prenatal diagnosis · 2022

Motion corrected fetal body magnetic resonance imaging provides reliable 3D lung volumes in normal and abnormal fetuses.

Davidson Joseph, Uus Alena, Egloff Alexia, van Poppel Milou, Matthew Jacqueline, Steinweg Johannes, Deprez Maria, Aertsen Michael, Deprest Jan, Rutherford Mary

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To calculate 3D-segmented total lung volume (TLV) in fetuses with thoracic anomalies using deformable slice-to-volume registration (DSVR) with comparison to 2D-manual segmentation. To establish a normogram of TLV calculated by DSVR in healthy control fetuses.

METHODS

A pilot study at a single regional fetal medicine referral centre included 16 magnetic resonance imaging (MRI) datasets of fetuses (22-32 weeks gestational age). Diagnosis was CDH (n = 6), CPAM (n = 2), and healthy controls (n = 8). Deformable slice-to-volume registration was used for reconstruction of 3D isotropic (0.85 mm) volumes of the fetal body followed by semi-automated lung segmentation. 3D TLV were compared to traditional 2D-based volumetry. Abnormal cases referenced to a normogram produced from 100 normal fetuses whose TLV was calculated by DSVR only.

RESULTS

Deformable slice-to-volume registration-derived TLV values have high correlation with the 2D-based measurements but with a consistently lower volume; bias -1.44 cm3 [95% limits: -2.6 to -0.3] with improved resolution to exclude hilar structures even in cases of motion corruption or very low lung volumes.

CONCLUSIONS

Deformable slice-to-volume registration for fetal lung MRI aids analysis of motion corrupted scans and does not suffer from the interpolation error inherent to 2D-segmentation. It increases information content of acquired data in terms of visualising organs in 3D space and quantification of volumes, which may improve counselling and surgical planning.

Для цитирования: Davidson Joseph, Uus Alena, Egloff Alexia, van Poppel Milou, Matthew Jacqueline, Steinweg Johannes, Deprez Maria, Aertsen Michael, Deprest Jan, Rutherford Mary. Motion corrected fetal body magnetic resonance imaging provides reliable 3D lung volumes in normal and abnormal fetuses.. Prenatal diagnosis. 2022. DOI: 10.1002/pd.6129.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.