MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00007632-199406000-00017

Медицинская библиотека · Spine · 1994

Neurologic injury after insertion of laminar hooks during Cotrel-Dubousset instrumentation.

Been H D, Kalkman C J, Traast H S, Ongerboer de Visser B W

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND DATA: Although the use of Cotrel-Dubousset (CD) instrumentation has improved results of operative treatment of scoliotic deformities, this technique may be associated with increased risk of neurologic injury.

CASE HISTORIES: Two cases of neurologic complications immediately after insertion of lumbar laminar hooks during CD instrumentation for correction of scoliosis are reported.

METHODS

Between 1986 and 1992, the authors performed 220 CD instrumentations for various spinal deformities. All patients were monitored with posterior tibial nerve somatosensory cortical evoked potentials (PTN-SSEPs).

CONCLUSION

These cases demonstrate that caution should be exercised during introduction of laminar hooks on the concave side during CD instrumentation for scoliotic deformities. Continuous neurophysiologic monitoring of spinal cord conduction may aid in early detection of local compression at the spinal cord or cauda equina level.

Для цитирования: Been H D, Kalkman C J, Traast H S, Ongerboer de Visser B W. Neurologic injury after insertion of laminar hooks during Cotrel-Dubousset instrumentation.. Spine. 1994. DOI: 10.1097/00007632-199406000-00017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.