MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.biomaterials.2016.08.038

Медицинская библиотека · Biomaterials · 2016

Studies of chain substitution caused sub-fibril level differences in stiffness and ultrastructure of wildtype and oim/oim collagen fibers using multifrequency-AFM and molecular modeling.

Li Tao, Chang Shu-Wei, Rodriguez-Florez Naiara, Buehler Markus J, Shefelbine Sandra, Dao Ming, Zeng Kaiyang

СтатьяПоддержка NIH: внешняя программаПоддержка правительства СШАПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Molecular alteration in type I collagen, i.e., substituting the α2 chain with α1 chain in tropocollagen molecule, can cause osteogenesis imperfecta (OI), a brittle bone disease, which can be represented by a mouse model (oim/oim). In this work, we use dual-frequency Atomic Force Microscopy (AFM) and incorporated with molecular modeling to quantify the ultrastructure and stiffness of the individual native collagen fibers from wildtype (+/+) and oim/oim diseased mice humeri. Our work presents direct experimental evidences that the +/+ fibers have highly organized and compact ultrastructure and corresponding ordered stiffness distribution. In contrast, oim/oim fibers have ordered but loosely packed ultrastructure with uncorrelated stiffness distribution, as well as local defects. The molecular model also demonstrates the structural and molecular packing differences between +/+ and oim/oim collagens. The molecular mutation significantly altered sub-fibril structure and mechanical property of collagen fibers. This study can give the new insight for the mechanisms and treatment of the brittle bone disease.

Для цитирования: Li Tao, Chang Shu-Wei, Rodriguez-Florez Naiara, Buehler Markus J, Shefelbine Sandra, Dao Ming, Zeng Kaiyang. Studies of chain substitution caused sub-fibril level differences in stiffness and ultrastructure of wildtype and oim/oim collagen fibers using multifrequency-AFM and molecular modeling.. Biomaterials. 2016. DOI: 10.1016/j.biomaterials.2016.08.038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.