MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2022.114485

Медицинская библиотека · Biosensors & bioelectronics · 2022

Hemoglobin-catalyzed atom transfer radical polymerization for ultrasensitive electrochemical DNA detection.

Ma Nan, Liu Jingliang, Li Lianzhi, Huang Weibo, Qiu Wenhao, Zhang Jian, Kong Jinming, Zhang Xueji

СтатьяПеревод в очереди

Аннотация

The use of hemoglobin (Hb) to drive atom transfer radical polymerization (ATRP) process (Hb-ATRP) for detection of lung cancer related nucleic acid is firstly reported. Hb does not need to be treated prior to using indicating the potential for synthetic engineering in complex biological microenvironments without the need for in vitro techniques. Here, we report a new signal amplification strategy using Hb-mediated graft of nitronyl niroxide monoradical polymers as a signal-on electrochemical biosensor for ultralow level DNA highly selective detection. Building DNA biosensors includes: (i) the fixation of peptide nucleic acid (PNA) probe (no phosphate group) via the 5' terminus-SH; (ii) the modification of transition metal; (iii) Site-specific markers of Hb-ATRP promoter, and (iv) the grafting of polymers with electrochemical signal by Hb-ATRP process. Through the Hb-ATRP process of nitronyl nitroxide monoradical (TEMPO), the presence of a small amount of DNA can eventually result in calling a certain number of TEMPO redox tags. Obviously, the Hb-ATRP is a method of easy source of raw materials, simple operation and no need for complex equipment. The constructed biosensor, as expected, is highly selective and sensitive to target DNA. The detection limit can be calculated as 15.96 fM under optimal conditions. The excellent performance also shows that the constructed DNA biosensor is suitable for DNA screening and DNA concentration determination in complex sample matrix.

Для цитирования: Ma Nan, Liu Jingliang, Li Lianzhi, Huang Weibo, Qiu Wenhao, Zhang Jian, Kong Jinming, Zhang Xueji. Hemoglobin-catalyzed atom transfer radical polymerization for ultrasensitive electrochemical DNA detection.. Biosensors & bioelectronics. 2022. DOI: 10.1016/j.bios.2022.114485.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.