MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1536/ihj.54.129

Медицинская библиотека · International heart journal · 2013

Extrathoracic subclavian venipuncture by using only the J-type guidewire for permanent pacemaker electrode placement.

Nakata Akio, Harada Tomoya, Kontani Koichirou, Hirota Satoshi

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

Extrathoracic subclavian/axillar venipuncture is an accepted method for implanting pacemaker leads. Although several procedures have been reported, no standard method has been established yet. We evaluated the usefulness of a method in which only J-type guidewires are used. Between August 2011 and November 2012, 33 patients (20 men and 13 women; age, 77.5 ± 10.3 years) underwent permanent pacemaker lead insertion by extrathoracic subclavian venipuncture at our hospital. Thirty-two of the patients underwent primary implantation, whereas 1 patient required an additional lead because of lead fracture. The guidewires were inserted from the cubital vein to the subclavian vein. After the pacemaker pockets were created, we set the X-ray projection in the ipsilateral anterior oblique view. The distal edge of the guidewire was positioned on the ventral side of the first rib on fluoroscopy. The needle tip was positioned within the Ushaped distal tip of the J-type guidewire. The needle was held parallel to the X-ray angle and advanced towards the first rib until the tip entered the subclavian vein. The guidewire was inserted through the cubital vein in 31 patients, and through the femoral vein in 2 patients. Using this method, we successfully performed subclavian venipunctures in all 33 patients (total, 60 punctures) without any complications. Extrathoracic subclavian venipuncture using only a J-type guidewire is an easy, safe, and economical method for pacemaker lead implantation.

Для цитирования: Nakata Akio, Harada Tomoya, Kontani Koichirou, Hirota Satoshi. Extrathoracic subclavian venipuncture by using only the J-type guidewire for permanent pacemaker electrode placement.. International heart journal. 2013. DOI: 10.1536/ihj.54.129.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.