Embolic Agent Selection and Outcomes in Renal Angiomyolipoma Embolisation.

O'Shea Ross, Pendse Himanshu, Ho Kevin, Hasan Hasan, Wal Ross Vander, Wyk Matthys Van, Tibballs Jonathan, Dulku Gurjeet

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

PURPOSE: To evaluate whether embolic agent selection influences outcomes following selective arterial embolisation (SAE) of renal angiomyolipomas (r-AMLs) and to assess procedural safety and effects on renal function.

MATERIALS AND

METHODS

A retrospective observational study was performed of all r-AML SAEs undertaken at a tertiary institution between 2015 and 2024. Change in tumour size on pre- and 3-6-month post-procedural imaging was the primary outcome. Secondary outcomes included technical success, re-intervention rates, complications (Clavien-Dindo), renal function change and length of hospital stay. Outcomes were compared across embolic agents including microparticles, liquid embolic agents, coils and combined approaches.

RESULTS

Forty-nine patients (51 lesions) underwent angiography, with SAE attempted in 54 procedures. Technical success was achieved in 91%. Tumour size reduction occurred in 91% of lesions with follow-up imaging, with a mean reduction of 1.75 cm (p < 0.0001). Liquid embolic agents alone demonstrated the greatest mean tumour reduction with a mean reduction of 2.4 cm and a 0% re-intervention rate. Microparticles alone achieved significant size reduction with a low re-intervention rate, while coil-only embolisation was associated with inferior outcomes and higher re-intervention rates. Combined embolisation strategies achieved significant tumour reduction but did not outperform liquid agents alone. Complications occurred in 10% of patients and were predominantly minor. No patient required renal replacement therapy, and the median eGFR did not change significantly.

CONCLUSION

SAE is a safe and effective treatment for r-AML in both elective and emergency settings. Liquid embolic agents achieved the greatest tumour reduction with low re-intervention rates, while coil-only embolisation showed inferior outcomes and should be avoided where possible.

Для цитирования: O'Shea Ross, Pendse Himanshu, Ho Kevin, Hasan Hasan, Wal Ross Vander, Wyk Matthys Van, Tibballs Jonathan, Dulku Gurjeet. Embolic Agent Selection and Outcomes in Renal Angiomyolipoma Embolisation.. Journal of medical imaging and radiation oncology. 2026. DOI: 10.1111/1754-9485.70108.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.