Journal of pediatric urology · 2016
Modified tubularized incised plate urethroplasty in distal hypospadias repair: Stepwise technique with validated functional and cosmetic outcome.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Spinoit A-F, Radford A, Ashraf J, Gopal M, Subramaniam R
Аннотация
OBJECTIVE: To describe modification of the tubularized incised plate urethroplasty (TIP) for distal hypospadias, and assess its efficacy, and functional and cosmetic outcomes.
METHODS: A prospective evaluation of a consecutive series of patients operated for primary distal hypospadias was conducted at a tertiary reference center. A standardized modification of the TIP (mTIP) procedure was performed on a 10 French catheter. Clinical data were collected in a dedicated database. Intraoperative variables, postoperative complications and outcomes, by means of uroflowmetries and a validated (HOPE) questionnaire, were assessed. Efficacy was evaluated with the reported complications: functional outcome was evaluated with uroflowmetries and cosmetic assessment by a validated questionnaire (HOPE). A descriptive statistical analysis was performed.
RESULTS: Of the 112 boys operated between 30/09/2011 and 1/04/2014, 50 completed long-term follow-up with functional and esthetic evaluation, as required for inclusion. Median age at surgery was 25 months (range 14-156); median follow-up time was 21.5 months (range 6-48). Complications requiring re-intervention occurred in 2/50 boys. Uroflowmetry presented a bell-shaped curve in 47/50 boys, and the median HOPE score was 9.5 (range 7.6-10.0).
CONCLUSION: The mTIP procedure provided satisfactory long-term functional and cosmetic outcomes, as validated by uroflowmetries and standardized questionnaire.
METHODS: A prospective evaluation of a consecutive series of patients operated for primary distal hypospadias was conducted at a tertiary reference center. A standardized modification of the TIP (mTIP) procedure was performed on a 10 French catheter. Clinical data were collected in a dedicated database. Intraoperative variables, postoperative complications and outcomes, by means of uroflowmetries and a validated (HOPE) questionnaire, were assessed. Efficacy was evaluated with the reported complications: functional outcome was evaluated with uroflowmetries and cosmetic assessment by a validated questionnaire (HOPE). A descriptive statistical analysis was performed.
RESULTS: Of the 112 boys operated between 30/09/2011 and 1/04/2014, 50 completed long-term follow-up with functional and esthetic evaluation, as required for inclusion. Median age at surgery was 25 months (range 14-156); median follow-up time was 21.5 months (range 6-48). Complications requiring re-intervention occurred in 2/50 boys. Uroflowmetry presented a bell-shaped curve in 47/50 boys, and the median HOPE score was 9.5 (range 7.6-10.0).
CONCLUSION: The mTIP procedure provided satisfactory long-term functional and cosmetic outcomes, as validated by uroflowmetries and standardized questionnaire.