Size of atrial septal defect after balloon atrial septostomy does not correlate with immediate improvement in oxygenation.

Sehgal Kartik, Sehgal Kunal, Varma Suraj

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Transposition of great arteries is a common cyanotic heart defect. Balloon atrial septostomy aims to improve circulatory mixing and oxygenation. Previous studies have combined infants with intact ventricular septum and those with ventricular septal defect. Additionally, the septostomy was performed much later after birth. The objectives were to ascertain any correlation between the atrial septal defect size and oxygenation, before and after septostomy, as well the change in parameters pre-post procedure.

METHODS

We performed an audit of the last 10 years of clinical and echocardiographic data (2010-2020) for infants with transposition of great arteries with intact ventricular septum. A pediatric cardiologist, masked to clinical data, reviewed the images.

RESULTS

Our study of 25 infants with transposition of great arteries with intact ventricular septum noted that the procedure was performed at a median [interquartile range (IQR)] of 3 (2, 4) hours after birth. Prostaglandin was administered to the majority of infants [20/25 (80%)]. While significant increases in partial pressure of oxygen (24±5 vs 40±6 mmHg, p<0.001) and preductal oxygen saturations (67%±18% vs 81%±11%, p=0.003) were noted, and while the atrial septal defect increased in size from 1.8±0.6 vs 4.8±0.7 mm (p<0.001), no correlation was noted between atrial septal defect size and oxygen saturations.

CONCLUSIONS

In our study of infants with transposition of great arteries and intact ventricular septum managed with balloon atrial septostomy, no correlation was noted between the atrial septal defect size and oxygen saturations. Pulmonary vascular resistance and pulmonary blood flow may be important physiological variables determining oxygenation.

Для цитирования: Sehgal Kartik, Sehgal Kunal, Varma Suraj. Size of atrial septal defect after balloon atrial septostomy does not correlate with immediate improvement in oxygenation.. World journal of pediatric surgery. 2021. DOI: 10.1136/wjps-2020-000224.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.