MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1034/j.1600-0412.2002.810911.x

Медицинская библиотека · Acta obstetricia et gynecologica Scandinavica · 2002

Arterial and ductus venosus Doppler in fetuses with absent or reverse end-diastolic flow in the umbilical artery: correlation with short-term perinatal outcome.

Müller Thomas, Nanan Ralph, Rehn Monika, Kristen Peter, Dietl Johannes

СтатьяПеревод в очереди

Аннотация

BACKGROUND

High perinatal morbidity and mortality rates have been reported in association with absent or reverse end-diastolic flow velocities in the umbilical artery. Doppler of fetal venous blood flow might be a helpful instrument for predicting fetal outcome. However, clinical data addressing this issue are rare. Thus, the aim of this study was to evaluate arterial and ductus venosus blood flow velocities as a predictor of short-term outcome in fetuses with umbilical absent or reverse end-diastolic flow velocities.

METHODS

Thirty-five high-risk single pregnancies complicated by umbilical absent or reverse end-diastolic flow velocities were monitored by serial measurement of the pulsatility index of the umbilical artery, middle cerebral artery, and ductus venosus waveforms over a period of 1-75 days.

RESULTS

The mean observation period between first detection of an umbilical absent or reverse end-diastolic flow velocity and delivery was 8.9 days. A significant correlation was found between parameters of short-term perinatal outcome (art. pH, art. base excess, development of intraventricular hemorrhage, mortality) and end-diastolic flow velocity waveform or pulsatility index of the ductus venosus waveform, but not with arterial Doppler parameters. Gestational age proved to be the best predictor for duration of assisted ventilation and development of respiratory distress syndrome.

CONCLUSIONS

Our results indicate that in high-risk pregnancies with umbilical absent or reverse end-diastolic flow velocities, determination of blood flow velocities in the ductus venosus is a useful additional parameter for prediction of fetal outcome and for timing delivery.

Для цитирования: Müller Thomas, Nanan Ralph, Rehn Monika, Kristen Peter, Dietl Johannes. Arterial and ductus venosus Doppler in fetuses with absent or reverse end-diastolic flow in the umbilical artery: correlation with short-term perinatal outcome.. Acta obstetricia et gynecologica Scandinavica. 2002. DOI: 10.1034/j.1600-0412.2002.810911.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.