MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/molecules27217247

Медицинская библиотека · Molecules (Basel, Switzerland) · 2022

Development of an Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry Method for Hydroxylated Polychlorinated Biphenyls in Animal-Derived Food.

Zhao Wenyu, Cui Na, Huang Yuan, Wang Zihao, Wang Peilong, Liang Haijun, Wang Ruiguo, Su Xiaoou

СтатьяПеревод в очереди

Аннотация

Hydroxylated polychlorinated biphenyls (OH-PCBs) are a group of metabolites biotransformed from polychlorinated biphenyls by animals with higher toxicities than their parent compounds. The present work developed and validated an analytical method for determinating penta-, hexa-, and hepta-chlorine substituted OH-PCBs in animal-derived food based on ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) with isotope-dilution. The target analytes were extracted with a 50% n-hexane/dichloromethane (v/v), purified by sulfuric acid-silica gel, and separated by 5% hydrated silica gel, achieving a final concentration of 100 times before injection to LC-MS/MS. The limits of detection (LOD) and quantification (LOQ) for target OH-PCBs were within the ranges of 0.003-0.010 μg/kg and 0.009-0.030 μg/kg, respectively. Average recoveries ranged between 76.7% and 116.5%, with relative standard deviations of less than 18.4%. The proposed method is simple, time-saving, sensitive, and accurate, making it a powerful tool for risk monitoring of OH-PCBs in animal-derived food.

Для цитирования: Zhao Wenyu, Cui Na, Huang Yuan, Wang Zihao, Wang Peilong, Liang Haijun, Wang Ruiguo, Su Xiaoou. Development of an Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry Method for Hydroxylated Polychlorinated Biphenyls in Animal-Derived Food.. Molecules (Basel, Switzerland). 2022. DOI: 10.3390/molecules27217247.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.