Journal of neonatal-perinatal medicine · 2019
Rescue high frequency ventilation for congenital diaphragmatic hernia.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Attar M A, Dechert R E, Donn S M
Аннотация
INTRODUCTION: High frequency jet (HFJV) and oscillatory (HFOV) ventilation were used to rescue newborns with congenital diaphragmatic hernia (CDH), who failed conventional mechanical ventilation (CV). Changes in ventilator settings and pulmonary gas exchange were evaluated following transition to high frequency ventilation (HFV).
METHODS: Records of patients with CDH rescued with HFV prior to surgical intervention between 2006 and 2015 were reviewed. Mean airway pressure (Pāw) and arterial blood gases during CV and those obtained within the first hour of HFV were compared. A composite repeated measure analysis was performed to evaluate longitudinal and intergroup variances.
RESULTS: Twenty-seven patients were rescued from CV, 16 by HFJV and 11 by HFOV. The two groups had similar gestational ages and birth weights. Prior to HFV, both groups had similar Pāw, PaCO2, FiO2 and PaO2. HFV was associated with a significant improvement in ventilation, and the rate of decrease of PaCO2 was no different between groups. There was a significantly higher increase in Pāw increase with HFOV compared to HFJV.
CONCLUSIONS: In newborns with CDH rescued with HFV, ventilation improved but Pāw was significantly lower in patients supported with HFJV compared to HFOV.
METHODS: Records of patients with CDH rescued with HFV prior to surgical intervention between 2006 and 2015 were reviewed. Mean airway pressure (Pāw) and arterial blood gases during CV and those obtained within the first hour of HFV were compared. A composite repeated measure analysis was performed to evaluate longitudinal and intergroup variances.
RESULTS: Twenty-seven patients were rescued from CV, 16 by HFJV and 11 by HFOV. The two groups had similar gestational ages and birth weights. Prior to HFV, both groups had similar Pāw, PaCO2, FiO2 and PaO2. HFV was associated with a significant improvement in ventilation, and the rate of decrease of PaCO2 was no different between groups. There was a significantly higher increase in Pāw increase with HFOV compared to HFJV.
CONCLUSIONS: In newborns with CDH rescued with HFV, ventilation improved but Pāw was significantly lower in patients supported with HFJV compared to HFOV.
Предметные рубрики MeSH
Blood Gas AnalysisExtracorporeal Membrane OxygenationFemaleHernias, Diaphragmatic, CongenitalHerniorrhaphyHigh-Frequency Jet VentilationHigh-Frequency VentilationHumansInfant, NewbornMalePartial PressurePressurePulmonary Gas ExchangeRespiration, ArtificialRespiratory InsufficiencyRetrospective Studies