MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/openhrt-2025-003628

Медицинская библиотека · Open heart · 2025

Artificial intelligence-based assessment of central aortic haemodynamics using non-invasive pulse wave analysis in constrictive pericarditis.

Suleiman Mathieu N, Dewald Oliver, Dreher Helena, Kaemmerer-Suleiman Ann-Sophie, Klawonn Frank, Middeke Martin, Pittrow Robert, Harig Frank, Mellert Fritz

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Constrictive pericarditis (CP) is a rare but significant pericardial disease resulting in impaired ventricular filling and heart failure symptoms, often following cardiac surgery. Its clinical presentation complicates diagnosis, mimicking other causes of heart failure. Recent technological advances, including artificial intelligence (AI)-based non-invasive pulse wave analysis (AI-PWA), have the potential for improved haemodynamic assessment and clinical decision-making.

OBJECTIVES

This study evaluates the clinical utility of AI-PWA in assessing central aortic blood pressure (CABP), arterial stiffness and cardiac function in CP.

METHODS

This prospective case-control study enrolled 12 adult CP patients and 12 age- and sex-matched healthy controls. CABP and peripheral blood pressure (PBP) were measured using the VascAssist2. Haemodynamic parameters, including pulse wave velocity (PWV), augmentation index@75 (AIx@75), cardiac index, stroke volume and dP/dtmax, were assessed and compared between groups.

RESULTS

CP patients showed significantly lower mean CABP than systolic PBP (101.8±23.4 mm Hg vs 112.3±22.9 mm Hg). PWV showed elevated values (>9 m/s) in nnn (42%) of cases, indicating increased arterial stiffness (8.88±1.94 m/s). AIx@75 was higher in CP patients (22.55±8.36%) compared with controls (16.38±6.53%), reflecting increased wave reflection, increased systemic vascular resistance or enhanced aortic compliance. Cardiac performance was notably impaired in the CP group, with reduced stroke volume (64.8±18.8 mL vs 94.9±25.0 mL, p=0.003) and dP/dtmax (724.9±228.2 mm Hg/s vs 1055.3±203.2 mmHg/s, p=0.0011), indicating impaired ventricular function. The heart failure index was significantly higher in CP patients (31.8±18.3% vs . 6.4±6.5%, p<0.001), indicating substantial functional compromise.

CONCLUSION

AI-PWA provides clinically relevant insights into central haemodynamics and arterial stiffness in CP patients. This non-invasive approach may enhance diagnosis and management of CP and should be considered for integration into routine cardiologic evaluation protocols.

Для цитирования: Suleiman Mathieu N, Dewald Oliver, Dreher Helena, Kaemmerer-Suleiman Ann-Sophie, Klawonn Frank, Middeke Martin, Pittrow Robert, Harig Frank, Mellert Fritz. Artificial intelligence-based assessment of central aortic haemodynamics using non-invasive pulse wave analysis in constrictive pericarditis.. Open heart. 2025. DOI: 10.1136/openhrt-2025-003628.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.