Feller Christina N, Awad Ahmed J, Nelson Mary Elizabeth S, Ketchum Nicholas, Pahapill Peter A

Аннотация

OBJECTIVES: Intrathecal baclofen (ITB) is a cost-effective therapy for patients with severe spasticity. The most common complications are catheter-related complications (CRCs) including kinking/occlusion, blockage, migration, fracture, disconnection, and CSF leak. Our objective was to determine the CRC rate in a large cohort of adults with newly implanted ITB pump systems with polymer reinforced silicone catheters.

MATERIALS AND METHODS: This is a retrospective study of a prospectively maintained database consisting of patients who had undergone implantation of ITB pump systems with Ascenda (Medtronic, Minneapolis) catheters from 2013 to 2020. Over this seven-year period, 141 patients underwent ITB pump system implantations; 126 of which had a minimum of one-year follow-up.

RESULTS: The 126 patients with a minimum of one year follow-up (average 43 month; range 12-89), had an average age of 51 years (63% male). Severe spasticity was due to spinal cord injury (38%), traumatic brain injury (15%), cerebral palsy (13%), multiple sclerosis (11%), stroke (10%), and other (13%). Nine (7.1%) CRCs occurred in 7 (5.6%) patients (median 6 mo. post-implant): 5 intrathecal catheter occlusions (range 3-52 months post-implant), two fractures in one patient (6 months), one disconnection at the catheter pump interface (2 months), and one due to kinking at 84 months No migrations occurred.

CONCLUSIONS: Reported CRCs have been high for ITB pump systems. Ours is the first large cohort, long-term study of CRCs related to reinforced catheters; additionally, our low CRC rate compares favorably to previously published data. Thus, implantation of reinforced catheters may be associated with a low CRC rate.