Infection and drug resistance · 2021
Multiplex Real-Time Polymerase Chain Reaction on Sputum for the Diagnosis of Pneumocystis jirovecii Pneumonia in Children: A Retrospective Study.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Jiang Juan, Wang Xia, He Jian, Liao Donglei, Deng Xiaolu
Аннотация
BACKGROUND: Pneumocystis jirovecii pneumonia (PCP) is a serious opportunistic infection in immunocompromised children. Real-time polymerase chain reaction (PCR) is widely used for the diagnosis of PCP due to its good accuracy. However, the diagnostic performance of multiplex real-time PCR on sputum in children with PCP has never been explored.
METHODS: Medical records of 63 consecutive pediatric patients were analyzed retrospectively, including 13 cases with PCP and 50 with non-PCP pneumonia. Pneumocystis jirovecii (P. jirovecii) and other co-pathogens detected by multiplex real-time PCR in sputum samples were summarized. Using clinical composite diagnosis as the reference standard, we further compared the diagnostic performance of multiplex real-time PCR to combined serological markers (1,3)-β-D-glucan plus lactate dehydrogenase. Additionally, modifications of antimicrobial treatment for pediatric PCP patients after the report of multiplex real-time PCR results were reviewed.
RESULTS: In children with PCP, nonproductive cough and shortness of breath were more common, lymphocyte count in peripheral blood was markedly lower, and serum levels of (1,3)-β-D-glucan and lactate dehydrogenase were much higher than non-PCP group. Multiplex real-time PCR reached a sensitivity of 100% in diagnosing PCP, which was better than serum (1,3)-β-D-glucan plus lactate dehydrogenase (76.9%). Its specificity (98.0%) significantly surpassed serum (1,3)-β-D-glucan plus lactate dehydrogenase (84.4%). Furthermore, multiplex real-time PCR showed a good performance in identifying co-pathogens in sputum of pediatric PCP patients. Cytomegalovirus, Epstein-Barr virus and Streptococcus pneumoniae were the most common co-pathogens in these patients. Initial antimicrobial treatment was modified in 76.9% of children with PCP after the report of PCR results.
CONCLUSION: Multiplex real-time PCR on sputum is a diagnostic tool with good performance for the identification of P. jirovecii as well as co-pathogens in children with PCP. Sputum may be an alternative to bronchoalveolar lavage fluid for PCR assay in children when bronchoscopic examination is not feasible.
METHODS: Medical records of 63 consecutive pediatric patients were analyzed retrospectively, including 13 cases with PCP and 50 with non-PCP pneumonia. Pneumocystis jirovecii (P. jirovecii) and other co-pathogens detected by multiplex real-time PCR in sputum samples were summarized. Using clinical composite diagnosis as the reference standard, we further compared the diagnostic performance of multiplex real-time PCR to combined serological markers (1,3)-β-D-glucan plus lactate dehydrogenase. Additionally, modifications of antimicrobial treatment for pediatric PCP patients after the report of multiplex real-time PCR results were reviewed.
RESULTS: In children with PCP, nonproductive cough and shortness of breath were more common, lymphocyte count in peripheral blood was markedly lower, and serum levels of (1,3)-β-D-glucan and lactate dehydrogenase were much higher than non-PCP group. Multiplex real-time PCR reached a sensitivity of 100% in diagnosing PCP, which was better than serum (1,3)-β-D-glucan plus lactate dehydrogenase (76.9%). Its specificity (98.0%) significantly surpassed serum (1,3)-β-D-glucan plus lactate dehydrogenase (84.4%). Furthermore, multiplex real-time PCR showed a good performance in identifying co-pathogens in sputum of pediatric PCP patients. Cytomegalovirus, Epstein-Barr virus and Streptococcus pneumoniae were the most common co-pathogens in these patients. Initial antimicrobial treatment was modified in 76.9% of children with PCP after the report of PCR results.
CONCLUSION: Multiplex real-time PCR on sputum is a diagnostic tool with good performance for the identification of P. jirovecii as well as co-pathogens in children with PCP. Sputum may be an alternative to bronchoalveolar lavage fluid for PCR assay in children when bronchoscopic examination is not feasible.