Медицинская библиотека · Journal of orthopaedic trauma · 2013

The reconstruction of tibial metaphyseal comminution using hybrid frames in severe tibial plafond fractures.

Katsenis Dimitris, Triantafillis Vassilis, Chatzicristos Marios, Dendrinos George

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate the treatment alternatives for the management of the metaphyseal tibial comminution in severe plafond fractures, and to investigate the role of the fibula fracture fixation.

DESIGN

Retrospective clinical study.

SETTING

Level-2 trauma hospital.

PARTICIPANTS

Patients with highly comminuted tibial plafond fractures.

INTERVENTION: All patients were treated with open reduction and internal fixation of the articular surface and external fixation of the metaphyseal fracture. If metaphyseal comminution was minimal, bone graft was applied and the fibular was plated (group 1); if comminution was between 1 and 3 cm, acute shortening and distraction osteogenesis was performed (group 2); and if comminution was >3 cm, distraction osteogenesis without acute shortening was performed (group 3).

MAIN OUTCOME MEASUREMENTS: Radiographic union, AOFAS ankle score.

RESULTS

Of 30 fractures, 15 fractures (50%) had an anatomic reduction of the joint. Union occurred in all but 2 fractures. Group 1 fractures healed at an average of 19 weeks (16-22). Four fractures had associated malalignment problems. The mean AOFAS score was 72.5 (range 45-100). Group 2 fractures healed at an average of 18.3 weeks (16-21). One fracture healed with 5-degrees of angulation. Group 3 fractures healed at an average of 17.5 weeks (14-24). Two fractures healed with malalignment. When groups 2 and 3 were combined to evaluate the AOFAS outcome for fractures treated with distraction osteogenesis, a score of 75.83 was obtained (45-90). There was no difference between the Group 1 versus combined Groups 2/3 with regard to this latter score (P = 0.372). Additionally, when fibula fixation (Group 1) was compared with those fractures where it was not performed (groups 2/3), no difference was seen (P = 0.276).

CONCLUSIONS

The reconstruction of severe tibial plafond fractures treated with small wire hybrid fixation may be achieved by different techniques leading to a satisfactory result. The fixation of the fibula fracture is dependent mainly on the treatment chosen for the management of the metaphyseal lesion.

LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Katsenis Dimitris, Triantafillis Vassilis, Chatzicristos Marios, Dendrinos George. The reconstruction of tibial metaphyseal comminution using hybrid frames in severe tibial plafond fractures.. Journal of orthopaedic trauma. 2013. DOI: 10.1097/bot.0b013e31825cf521.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.