MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Annali italiani di chirurgia · 2014

Intraoperative recurrent laryngeal nerve monitoring in thyroid surgery Evaluation of its use in terms of "spending review".

Sanguinetti Alessandro, Parmeggiani Domenico, Lucchini Roberta, Monacelli Massimo, Triola Roberta, Avenia Stefano, Conti Claudia, Conzo Giovanni, Avenia Nicola

Сравнительное исследованиеСтатьяОбзорПеревод в очереди

Аннотация

BACKGROUND

Intra Operative Nerve Monitoring (IONM) has been used in head and neck surgery since the 1970s. Its utilization for monitoring and protecting the recurrent laryngeal nerve, however, is a controversial subject. This paper details the use, value, and cost of this technology within a single institution.

METHODS

We conducted a retrospective chart review, analysis of surgery time with and without IONM, analysis of postoperative vocal cord function, and review of the literature

RESULTS

IONM did not reduce the operative time during total thyroidectomies in our experience. Use of IONM increased the cost of each surgery by € 450. IONM did not decrease the number of injured nerves (postoperative paresis).

CONCLUSIONS

IONM has proven to be highly useful in certain circumstances but has not been definitively proven to protect the nerve any more effectively than the gold standard of nerve visualization. In our study, the use of IONM did not reduce the time of thyroid surgery and did increase the cost. While IONM may, in special clinical circumstances such as revision and malignant thyroid surgery, increase the value of the operation, its use for every thyroid surgery does not appear to be cost effective or valuable to the patient.

Для цитирования: Sanguinetti Alessandro, Parmeggiani Domenico, Lucchini Roberta, Monacelli Massimo, Triola Roberta, Avenia Stefano, Conti Claudia, Conzo Giovanni, Avenia Nicola. Intraoperative recurrent laryngeal nerve monitoring in thyroid surgery Evaluation of its use in terms of "spending review".. Annali italiani di chirurgia. 2014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.