MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cca.2011.09.011

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2011

Perinatal asphyxia: kidney failure does not affect S100B urine concentrations.

Risso Francesco M, Serpero Laura D, Zimmermann Luc J I, Gavilanes Antonio W D, Frulio Rosanna, Michetti Fabrizio, Florio Pasquale, Bashir Moataza, Iskander Iman, Mufeed Hala, Aboulgar Hanna, Gazzolo Diego

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

S100B protein is a well-established marker of brain damage. Its importance in urine assessment is the convenience of a collection and sampling procedure that can be repeated without risk for the newborn. Since S100B is mainly eliminated by the kidneys and perinatal asphyxia (PA) is often associated with kidney failure we investigated whether S100B release might be kidney-mediated, thereby modifying the protein's reliability as a brain-damage marker.

METHODS

We examined a cohort of healthy (n=432) and asphyxiated newborns (n=32) in whom kidney function parameters (blood urea and creatinine concentrations and urine gravity) and urine S100B concentrations were assessed in the first hours after birth. Data were analyzed by multiple logistic regression analysis with S100B as independent variable among a variety of clinical and laboratory monitoring parameters.

RESULTS

S100B urine concentrations were significantly higher (P<0.01) in PA newborns than controls. No significant correlations (P>0.05, for all) between total urine S100B levels and kidney function parameters such as creatinine (r=0.03), urea (r=0.04) and urine gravity (r=0.06) were found. Multiple logistic regression analysis of a series of clinical and laboratory monitoring parameters (odds ratio at sampling: 9.47) with S100B as independent variable showed a positive significant correlation only between S100B levels (P<0.001) and the occurrence of PA.

CONCLUSION

The present study shows that altered kidney function is not an adverse and/or confounding factor in urine S100B assessment and marks a new step towards the introduction of longitudinal monitoring of brain constituents in clinical practice.

Для цитирования: Risso Francesco M, Serpero Laura D, Zimmermann Luc J I, Gavilanes Antonio W D, Frulio Rosanna, Michetti Fabrizio, Florio Pasquale, Bashir Moataza, Iskander Iman, Mufeed Hala, Aboulgar Hanna, Gazzolo Diego. Perinatal asphyxia: kidney failure does not affect S100B urine concentrations.. Clinica chimica acta; international journal of clinical chemistry. 2011. DOI: 10.1016/j.cca.2011.09.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.