Persistence of translocations after accidental exposure to ionizing radiation.
Аннотация
PURPOSE: To assess the validity of translocations for retrospective biodosimetry using FISH chromosome painting of peripheral lymphocytes in repeated samples of people accidentally exposed to radiation.
MATERIALS AND
METHODS
Blood samples from five people exposed to mainly whole-body irradiation of gamma-rays from a radiation accident in Estonia in 1994 were taken at 2-4 month intervals. A total of eight samplings were carried out, including one directly after the accident. Fluorescence in situ hybridization with probes for chromosomes 1, 2 and 4 was performed on metaphase preparations from 48 h whole blood cultures; 1500 cells were scored from each individual per time point.
RESULTS
Translocations remained relatively stable during 2 years after exposure in all subjects. A noticeable decrease in complete translocation yields and a significant decrease in incomplete translocations were observed in one person. In addition to whole-body exposure, he had also been exposed to partial-body irradiation. Due to the overall persistence of translocations, dose estimates were very similar throughout the 2 year period. A rapid decline in dicentric frequencies was noted during the first year after exposure.
CONCLUSIONS
The results suggest that during 2 years the yield of translocations in peripheral lymphocytes remained at a constant level after whole-body exposure. This finding supports the use of translocations for retrospective dosimetry, at least within this relatively short period of follow-up. In the case of partial-body irradiation, however, the elimination of co-existing unstable aberrations reduced the translocation yield over time. Follow-up will be continued in order to determine the stability of translocations over longer times.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.