A new electrocautery pleural biopsy technique using an insulated-tip diathermic knife during semirigid pleuroscopy.

Sasada Shinji, Kawahara Kunimitsu, Kusunoki Yoko, Okamoto Norio, Iwasaki Teruo, Suzuki Hidekazu, Kobayashi Masashi, Hirashima Tomonori, Matsui Kaoru, Ohta Mitsunori, Miyazawa Teruomi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The biopsy size obtained with standard flexible forceps (SFF) during semirigid pleuroscopy is often insufficient for pathological examination. An insulated-tip diathermic knife (IT knife) allows safe resection of a larger lesion during gastrointestinal endoscopy. We sought to validate an electrocautery pleural biopsy technique using the IT knife during semirigid pleuroscopy. We compared the diagnosis of specimens obtained using the IT knife and SFF in 20 subjects with unexplained pleural effusion, and reviewed pleuroscopic parameters such as complications, procedure time, and diameter of the specimens.

METHODS

After injecting saline with lidocaine and epinephrine below the affected pleura, the lesion was incised in a circular shape with full thickness by manipulating the IT knife.

RESULTS

Diagnostic yields from specimens obtained with the IT knife and SFF were 85% (17 of 20 cases) and 60% (12 of 20 cases), respectively. The IT knife biopsy was superior to SFF in 8 of 20 patients (malignant pleural mesothelioma in three, nonspecific inflammation in two, metastatic breast cancer in one, and tuberculosis in one). These pleural lesions revealed thickened, smooth abnormal appearances. The overall diagnostic yield for both IT knife and SFF was 100%. Median time of the procedure, from first pleural injection to specimen removal, was 21 min (range 12-92 min), and median diameter of specimen was 13 mm (range 6-23 mm). There were no severe complications during the procedure.

CONCLUSIONS

Electrocautery biopsy using the IT knife during semirigid pleuroscopy has great potential for diagnosing smooth abnormal pleura which are difficult to biopsy with SFF.

Для цитирования: Sasada Shinji, Kawahara Kunimitsu, Kusunoki Yoko, Okamoto Norio, Iwasaki Teruo, Suzuki Hidekazu, Kobayashi Masashi, Hirashima Tomonori, Matsui Kaoru, Ohta Mitsunori, Miyazawa Teruomi. A new electrocautery pleural biopsy technique using an insulated-tip diathermic knife during semirigid pleuroscopy.. Surgical endoscopy. 2009. DOI: 10.1007/s00464-008-0263-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.