The Journal of antimicrobial chemotherapy · 2011
Enhanced gonococcal antimicrobial surveillance in the era of ceftriaxone resistance: a real-time PCR assay for direct detection of the Neisseria gonorrhoeae H041 strain.
Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Goire Namraj, Ohnishi Makoto, Limnios Athena E, Lahra Monica M, Lambert Stephen B, Nimmo Graeme R, Nissen Michael D, Sloots Theo P, Whiley David M
Аннотация
OBJECTIVES: Recent emergence of the extensively drug-resistant Neisseria gonorrhoeae H041 strain in Japan raises concerns that gonorrhoea may soon become untreatable and emphasizes the need for enhanced surveillance. In this study we developed a real-time PCR assay for direct detection of the H041 strain.
METHODS: Two real-time PCR assays for detection of the penA gene of the H041 strain, H041-PCR1 and H041-PCR2, were developed and evaluated in parallel. Assay performance was assessed using a panel of pathogenic and commensal Neisseria species (n = 167 strains) including the N. gonorrhoeae H041 strain and clinical specimens (n = 252) submitted for sexual health screening. The detection limits of the assays were compared with a standard N. gonorrhoeae real-time PCR method.
RESULTS: Both the H041-PCR1 and H041-PCR2 assays correctly detected the N. gonorrhoeae H041 strain and provided negative results for all other N. gonorrhoeae strains. However, only the H041-PCR2 assay proved to be specific when applied to the non-gonococcal Neisseria species and clinical samples. False-positive results in the H041-PCR1 included cross-reactions with two Neisseria subflava isolates and eight clinical specimens. DNA sequencing of these N. subflava strains revealed the presence of the penicillin-binding protein 2 Ala328Thr alteration previously only observed in the N. gonorrhoeae H041 strain.
CONCLUSIONS: The H041-PCR2 assay is suitable for direct detection of the N. gonorrhoeae H041 ceftriaxone-resistant strain in cultured and non-cultured samples.
METHODS: Two real-time PCR assays for detection of the penA gene of the H041 strain, H041-PCR1 and H041-PCR2, were developed and evaluated in parallel. Assay performance was assessed using a panel of pathogenic and commensal Neisseria species (n = 167 strains) including the N. gonorrhoeae H041 strain and clinical specimens (n = 252) submitted for sexual health screening. The detection limits of the assays were compared with a standard N. gonorrhoeae real-time PCR method.
RESULTS: Both the H041-PCR1 and H041-PCR2 assays correctly detected the N. gonorrhoeae H041 strain and provided negative results for all other N. gonorrhoeae strains. However, only the H041-PCR2 assay proved to be specific when applied to the non-gonococcal Neisseria species and clinical samples. False-positive results in the H041-PCR1 included cross-reactions with two Neisseria subflava isolates and eight clinical specimens. DNA sequencing of these N. subflava strains revealed the presence of the penicillin-binding protein 2 Ala328Thr alteration previously only observed in the N. gonorrhoeae H041 strain.
CONCLUSIONS: The H041-PCR2 assay is suitable for direct detection of the N. gonorrhoeae H041 ceftriaxone-resistant strain in cultured and non-cultured samples.