Медицинская библиотека · European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026

Radiological stability and functional performance of cementless modular long stems in revision hip arthroplasty: a minimum 4-year follow-up single-center experience.

Fahmy Mahmoud, Shawky Mostafa Ahmed, Zawam Sherif Hamdy

СтатьяПеревод в очереди

Аннотация

PURPOSE: Revision total hip arthroplasty (rTHA) with substantial femoral bone loss is technically demanding, requiring durable distal fixation, biomechanical restoration, and early functional recovery. Cementless modular long stems provide diaphyseal fixation with intraoperative adjustability, yet mid-term evidence across diverse revision indications remains limited. This prospective single-center study evaluated radiological stability, functional outcomes, and modifiable prognostic factors, particularly early weight bearing.

METHODS

Seventy-five patients underwent femoral rTHA with a cementless modular long-stem system between 2015 and 2020, achieving ≥ 4-year follow-up (mean 62 months). Indications included aseptic loosening (48%), periprosthetic fracture (29.3%), and two-stage reimplantation (16%); extended trochanteric osteotomy (ETO) was performed in 28%. Radiological evaluation assessed osseointegration, subsidence, and osteotomy union. Functional outcomes were measured using the Harris Hip Score (HHS), Oxford Hip Score (OHS), and EQ-VAS. Correlation and regression analyses examined relationships between bone defect grade, weight-bearing timing, and functional recovery.

RESULTS

Osseointegration was achieved in 94.6% of hips, with mean stem subsidence of 1.4 mm and complete ETO union. Functional scores improved significantly (HHS 44.2 → 87.6; OHS 22.3 → 40.5; EQ-VAS 54.6 → 82.1; all p < 0.001). Complications occurred in 9.2%, mainly superficial infection (5.3%) and dislocation (2.6%), with no aseptic loosening or modular junction failures. Earlier full weight bearing correlated with superior HHS (r = -0.47, p < 0.01). Four-year stem survival was 98.7%.

CONCLUSION

Cementless modular long stems provided reliable mid-term fixation, high osseointegration rates, and substantial functional improvement across varied revision indications. Low complication rates and absence of mechanical failures reinforce their utility in complex femoral revisions. Earlier achievement of full weight bearing was associated with superior functional outcomes.

Для цитирования: Fahmy Mahmoud, Shawky Mostafa Ahmed, Zawam Sherif Hamdy. Radiological stability and functional performance of cementless modular long stems in revision hip arthroplasty: a minimum 4-year follow-up single-center experience.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2026. DOI: 10.1007/s00590-026-04822-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.