High hip center technique using a biconical threaded Zweymüller cup in osteoarthritis secondary to congenital hip disease.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Christodoulou Nikolaos A, Dialetis Konstantinos P, Christodoulou Athanasios N
Аннотация
BACKGROUND: The high hip center technique used for a deficient acetabulum is reconstruction of the hip at a high center of rotation. In the literature, there is no consensus regarding the value of this technique.
QUESTIONS/PURPOSES: We investigated whether the new-generation biconical threaded Zweymüller cup fixed in a high nonanatomic position in patients with arthritis secondary to congenital hip disease experienced different rates of polyethylene wear and long-term survivorship when compared with anatomically positioned cups.
PATIENTS AND METHODS: We studied the polyethylene wear rate and Kaplan-Meier survivorship of 104 titanium threaded Zweymüller cups in 88 patients (81 females), placed in 70 hips at near-normal hip center and in 34 hips at a high hip center position at a distance of 31.1 to 60 mm (mean, 39.7 mm) from the interteardrop line. Minimum followup was 2 years (mean +/- SD, 8.6 +/- 3.5 years; range, 2-15 years).
RESULTS: The mean linear polyethylene wear rates in the near-normal and high hip center groups were not different (0.110 +/- 0.050 mm and 0.113 +/- 0.057 mm, respectively). The Kaplan-Meier 15-year cup survivorship rates with revision for any reason as an event of interest in the near-normal and high hip center groups also were not different (97.2% [95% confidence interval, 88.5%-99.3%] and 97.1% [95% confidence interval, 73.8%-99.3%], respectively).
CONCLUSIONS: The high hip center technique using a biconical threaded Zweymüller cup in patients with arthritis secondary to congenital hip disease results in a polyethylene wear rate and long-term cup survivorship comparable to those observed in anatomically positioned cups.
LEVEL OF EVIDENCE: Level III, therapeutic study. See the Guidelines for Authors for a complete description of level of evidence.
QUESTIONS/PURPOSES: We investigated whether the new-generation biconical threaded Zweymüller cup fixed in a high nonanatomic position in patients with arthritis secondary to congenital hip disease experienced different rates of polyethylene wear and long-term survivorship when compared with anatomically positioned cups.
PATIENTS AND METHODS: We studied the polyethylene wear rate and Kaplan-Meier survivorship of 104 titanium threaded Zweymüller cups in 88 patients (81 females), placed in 70 hips at near-normal hip center and in 34 hips at a high hip center position at a distance of 31.1 to 60 mm (mean, 39.7 mm) from the interteardrop line. Minimum followup was 2 years (mean +/- SD, 8.6 +/- 3.5 years; range, 2-15 years).
RESULTS: The mean linear polyethylene wear rates in the near-normal and high hip center groups were not different (0.110 +/- 0.050 mm and 0.113 +/- 0.057 mm, respectively). The Kaplan-Meier 15-year cup survivorship rates with revision for any reason as an event of interest in the near-normal and high hip center groups also were not different (97.2% [95% confidence interval, 88.5%-99.3%] and 97.1% [95% confidence interval, 73.8%-99.3%], respectively).
CONCLUSIONS: The high hip center technique using a biconical threaded Zweymüller cup in patients with arthritis secondary to congenital hip disease results in a polyethylene wear rate and long-term cup survivorship comparable to those observed in anatomically positioned cups.
LEVEL OF EVIDENCE: Level III, therapeutic study. See the Guidelines for Authors for a complete description of level of evidence.