BACKGROUND

We report our experience in aortic arch repair with the E-vita Open hybrid prosthesis and describe the changes in our technique over time.

METHODS

Between October 2013 and December 2019, 56 patients underwent a total aortic arch replacement with the E-vita Open hybrid prosthesis. The main indications were thoracic aorta aneurysm (n = 27) and acute type A aortic dissection (n = 18). We analyze the technique and results in the overall series, and compare both between our early (group I, 25 patients) and late experience (group II, 31 patients).

RESULTS

Overall in-hospital mortality was 7.1% (n = 4), and permanent stroke and spinal cord injury were 3.6% and 1.8%, respectively. Fifteen patients (26.8%) underwent a planned second procedure on the distal aorta: 13 endovascular, 1 open, and 1 hybrid. Survival at 1 and 3 years was 90.7% and 80.7%, respectively. Group II included more patients with acute dissection (45.2% vs 16%, P = .02), higher rates of bilateral cerebral perfusion (100% vs 64%, P < .001), left subclavian artery perfusion during lower body circulatory arrest (87.1% vs 0%, P < .001), early reperfusion (96.8% vs 40%, P < .001), and zone 0 to 2 distal anastomosis (100% vs 72%, P = .02). In-hospital mortality (3.2% vs 12%) and permanent stroke (0% vs 8%) tended to be lower in group II.

CONCLUSIONS

Total arch replacement with E-vita Open hybrid prosthesis in complex thoracic aorta disease is safe. One-stage treatment is feasible when pathology does not extend beyond the proximal descending thoracic aorta. In any case, it facilitates subsequent procedures on distal aorta if needed.

Для цитирования: Maroto Luis C, Carnero Manuel, Cobiella Javier, Beltrao Rosa, Villagrán Enrique, Reguillo Fernando, Pérez Daniel. Single-center experience and evolution of technique with the E-vita Open prosthesis.. Journal of cardiac surgery. 2020. DOI: 10.1111/jocs.14871.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.