m+Medelevator.RU
← Поиск публикаций
Resuscitation · 2026

Hemodynamic effects of TEE-guided adjustment of the area of the maximal compressions during cardiopulmonary resuscitation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chen Chia-Ching, Chen Tai-Yuan, Lin Lung-Chun, Wu Cheng-Yi, Wu Meng-Che, Hsu Shu-Hsien, Tay Joyce, Lien Wan-Ching

Аннотация

BACKGROUND: Real-time evidence on left ventricular (LV) parameters during cardiopulmonary resuscitation (CPR), especially before and after adjusting the area of maximal compression (AMC), is limited. This study used three-dimensional transesophageal echocardiography (3D-TEE) to assess LV parameters during resuscitation with and without AMC adjustment.

METHODS: Adult patients with non-traumatic out-of-hospital cardiac arrest (OHCA) were prospectively enrolled. The AMC was identified by two-dimensional (2D)-TEE and LV end-diastolic volume (EDV), and end-systolic volume (ESV) were measured by 3D-TEE to derive stroke volume (SV) and ejection fraction (EF). If AMC aligned with the LV (AMC-LV group), chest compressions were continued; otherwise, the site was adjusted (AMC-non-LV group) for optimal LV alignment and measurements repeated. End-tidal carbon dioxide (EtCO2) data were collected at the time of AMC identification and 1 min after AMC adjustment.

RESULTS: Nineteen patients were included. The AMC was located over the LV in 4 patients (21%), while 15 patients (79%) required TEE-guided AMC adjustment. In the AMC-non-LV group, SV (9 vs. 28.6 mL, p = 0.004), EF (20.4 vs. 60.8%, p < 0.0001) and EtCO2 (19 vs. 42 mmHg, p < 0.0001) increased significantly post-adjustment, reaching values comparable to the AMC-LV group. ROSC rates did not differ between the AMC-LV and AMC-non-LV groups (75% vs. 53%, p = 0.603).

CONCLUSIONS: 2D-TEE-guided identification and adjustment of AMC allowed targeted optimization of chest compressions. Approximately 80% of patients required AMC adjustment. 3D-TEE was used to quantify LV parameters. In patients undergoing AMC adjustment, significant improvements in SV and EF were observed, reaching levels comparable to those without adjustment.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты