MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2020.09.072

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2020

Outflow tract geometries are associated with adverse outcome indicators in repaired tetralogy of Fallot.

Shen Wan-Chen, Chen Chun-An, Chang Chung-I, Chen Yih-Sharng, Huang Shu-Chien, Wu Mei-Hwan, Wang Jou-Kou

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

A wide variety of right ventricular outflow tract (RVOT) and pulmonary artery (PA) geometries has been reported in patients with repaired tetralogy of Fallot (rTOF). We aimed to investigate the associations between RVOT/PA geometries and outcome indicators in a large rTOF cohort receiving non-conduit repair.

METHODS

Three-dimensional magnetic resonance angiographic images of 206 patients with rTOF who had a pulmonary regurgitation (PR) fraction ≥20% were reviewed. Patients' RVOT geometry was quantitatively classified into 4 distinct shapes (tubular, hourglass, pyramid, and inverted trapezoid). Bilateral PA size discrepancy was defined as the diameter of the smaller side being less than 70% of that of the bigger side.

RESULTS

Based on lateral projection of the 3-dimensional images, patients with an inverted trapezoid-shaped RVOT had the smallest RV end-diastolic volume index (EDVi) (108.7 ± 24.3 mL/m2) and pulmonary valve annulus diameter, and shortest QRS duration, whereas those with a pyramid-shaped RVOT had the largest RV EDVi (161.0 ± 44.6 mL/m2) and pulmonary valve annulus diameter. Similar trends of differences were also observed if such classifications were based on the frontal projections. Multivariable analysis revealed that RVOT shapes, subvalvular diameter, PR fraction, QRS duration, and the presence of bilateral PA size discrepancy were independent determinants of RV EDVi. Furthermore, having bilateral PA size discrepancy (25.2%) was independently associated with lower peak oxygen consumption (P = .041).

CONCLUSIONS

Distinct RVOT morphologies and branch PA size discrepancy are associated with variations in RV remodeling and exercise capacity in patients with rTOF. These findings may aid decision-making regarding reintervention for PR and branch PA size discrepancy.

Для цитирования: Shen Wan-Chen, Chen Chun-An, Chang Chung-I, Chen Yih-Sharng, Huang Shu-Chien, Wu Mei-Hwan, Wang Jou-Kou. Outflow tract geometries are associated with adverse outcome indicators in repaired tetralogy of Fallot.. The Journal of thoracic and cardiovascular surgery. 2020. DOI: 10.1016/j.jtcvs.2020.09.072.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.