Positive predictive value of the Becton Dickinson VIPER system and the ProbeTec GC Q x assay, in extracted mode, for detection of Neisseria gonorrhoeae.
Аннотация
OBJECTIVES
Performance of the new Becton Dickinson ProbeTec GC Q(x) assay on the BD VIPER platform was evaluated to ascertain whether confirmatory testing is required in our clinical setting.
METHODS
Positive predictive value (PPV) was determined by comparison with culture and a confirmatory nucleic acid amplification test (NAAT)-based Neisseria gonorrhoeae assay from genital and extragenital samples (rectal and pharyngeal) collected from a genitourinary medicine (GUM) clinic.
RESULTS
Among 14,223 clinical genital samples, 149 (1.0%) specimens were positive using the ProbeTec GC Q(x) assay, automated on the VIPER platform; 141 of these were confirmed by either culture or a real-time PCR targeting two gonococcal-specific targets (PPV 94.6%; 95% CI 90% to 98%). Among 840 pharyngeal samples, 26 (3.1%) were positive by the ProbeTec GC Q(x) assay; 13 were confirmed (PPV 50%; 95% CI 30% to 70%). Among 593 rectal samples, 17 tested positive by the ProbeTec GC Q(x) assay; all were confirmed (PPV 100%; 95% CI 80% to 100%).
CONCLUSIONS
The lower 95% CI of the PPV for the ProbeTec GC Q(x) assay for genital specimens was >90% in this GUM clinic population, and therefore confirmatory testing for genital specimens is not required. Confirmatory testing of pharyngeal and rectal samples should continue in line with national guidelines.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.